| Electronic Components Datasheet Search |
|
VCM101 Datasheet(PDF) 7 Page - List of Unclassifed Manufacturers |
|
|
|||||||||||||||||||||||||||||
VCM101 Datasheet(HTML) 7 Page - List of Unclassifed Manufacturers |
|
7 / 20 page ![]() 24 Mechanical pressure switches Principal technical data Principal technical data Valid for all pressure of the DCM, VCM, DNM, DWR, DGM, DNS and DDCM series that have a microswitch. The technical data of type-tested units may differ slightly (please refer to particular type sheet). Ex-i-version …500 Switch housing Pressure connection Switching function and connection scheme (applies only to version with microswitch) Switching capacity Mounting position Protection class (in vertical position) Explosion protection Code EC Type Examination Certificate Number Electrical connection Cabel entry Ambient temperature Medium temperature Relative humidity Switching point Hysteresis Vacuum Repetition accuracy of switching points Vibration resistance Mechanical durability (pressure sensor) Electronical durability (microswitch) Isolation values Oil and grease-free Diecast aluminium GDAISi 12 G 1/2" external thread (pressure gauge connection) and G 1/4" internal thread. 1/4" internal thread for DDCM differential pressure switches Floating changeover contact. With rising pressure single pole switching from 3–1 to 3–2 max.: 100mA, 24VDC min.: 2mA, 5VDC Vertical IP 65 II 1/2G Ex ia IIC T6 Ga/Gb II 1/2D Ex ia IIIC T80 °C IBExU12ATEX1040 Terminal connection M 16 x 1.5 –25 to +60 °C (exceptions: DWAM, DWAMV, SDBAM series –20 to +60 °C DGM and FD series: –25 to +60 °C DCM4016, 4025, 1000, VCM4156: –15 to +60 °C) Max. 60 °C 15 to 95 % (non-condensing) After removing switch housing cover Not adjustable Diecast aluminium GDAISi 12 G 1/2" external thread (pressure gauge connection) and G 1/4" internal thread. 1/4" internal thread for DDCM differential pressure switches Floating changeover contact. With rising pressure single pole switching from 3–1 to 3–2 3 A at 250 VAC 2 A at 250 VAC inductive 3 A at 24 VDC 0.1 A at 250 VDC min. 2 mA, 24 VDC Vertical IP 65 II 2G Ex d e IIC T6 Gb II 1/2D Ex ta/tb IIIC T80 °C Da/Db IBExU12ATEX1040 Terminal connection M 16 x 1.5 –20 to +60 °C Max. 60 °C 15 to 95 % (non-condensing) After removing switch housing cover Not adjustable Higher medium temperatures are possible provided the above limits for the switching device are ensured by suitable measures (e.g. siphon). All pressure switches can operate under vacuum. This will not damage the device. < 1 % of the working range (for pressure ranges > 1 bar). No significant deviations up to 4 g. With sinusoidal pressure application and room temperature, 10 x 106 switching cycles. The expected life depends to a very large extent on the type of pressure application, therefore this figure can serve only as a rough estimate. With pulsating pressure or pressure impacts in hydraulic systems, pressure surge reduction is recommended. 100.000 switching cycles at nominal current 8 A, 250 VAC. A reduced contact load increases the number of possible switching cycles. Overvoltage category III, contamination class 3, reference surge voltage 4000 V. Conformity to DIN VDE 0110 is confirmed. The parts of all pressure switches in contact with the medium are oil and grease-free (except the HCD…and DPS…series). The sensors are hermetically sealed and contain no seals (also see ZF1979, special packing). version (Ex-d) …700 |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |