Back Button ACT4751M Datasheet HTML 14Page - Qorvo, Inc ACT4751M Datasheet HTML 15Page - Qorvo, Inc ACT4751M Datasheet HTML 16Page - Qorvo, Inc ACT4751M Datasheet HTML 17Page - Qorvo, Inc ACT4751M Datasheet HTML 18Page - Qorvo, Inc ACT4751M Datasheet HTML 19Page - Qorvo, Inc ACT4751M Datasheet HTML 20Page - Qorvo, Inc ACT4751M Datasheet HTML 21Page - Qorvo, Inc ACT4751M Datasheet HTML 22Page - Qorvo, Inc Next Button
Zoom Inzoom in Zoom Outzoom out
 18 / 71 page
background image
ACT4751M
AEC-Q100, USB Fast Charger Power IC with 40V Input, 4A, Programmable
Output Voltage and Current
Register Bit Maps
Following sub-sections explain bit assignments of each I
2C register. Here are the meanings of each column in below bit
tables.
Bit #
Bit position (number)
Bit(s) Name
Bit(s) name
Def
Default value
Description
Description of the bit(s)
0x00 State-Machine
The register 0x00 is Read Only type. It indicates current position of the state-machine. See Control Logic.
Table 2. Register 0x00
Bit #
Bit(s) Name
Def
Description
7
0
(un-used bit)
6
0
(un-used bit)
5
0
(un-used bit)
4
0
(un-used bit)
3
State[3]
0
2
State[2]
0
1
State[1]
0
0
State[0]
0
See Table 3.
Table 3. State-Machine Bits [3:0]
Value (bin)
Value (hex)
Position of State-Machine
0000
0x00
No Power, in Under-Voltage Lock-Out
0001
0x01
Bias Ramp, initialing mini-buck
[1]
0010
0x02
Bias Reset
0011
0x03
Bias Ramp checking RADDR
[1]
0100
0x04
Bias Ramp
0101
0x05
Bias Ready checking RFREQ
[1]
0110
0x06
RFREQ Checking Loop
[2]
0111
0x07
Bias Ready
1000
0x08
Main-buck Ramp enabling main-buck
[1]
1001
0x09
Main-buck Ramp
1010
0x0A
Main-buck ON
1011
0x0B
Main-buck Shutdown
1100
0x0C
Main-buck Error
[1] Short transit, not staying loner at this position
[2] Not in the Table 27, see R
FREQ Checking Loop
ACT4751M Data Sheet, Rev. E, 16-Jul-2020
Subject to change without notice
18
www.qorvo.com



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com