Back Button ACT4751M Datasheet HTML 19Page - Qorvo, Inc ACT4751M Datasheet HTML 20Page - Qorvo, Inc ACT4751M Datasheet HTML 21Page - Qorvo, Inc ACT4751M Datasheet HTML 22Page - Qorvo, Inc ACT4751M Datasheet HTML 23Page - Qorvo, Inc ACT4751M Datasheet HTML 24Page - Qorvo, Inc ACT4751M Datasheet HTML 25Page - Qorvo, Inc ACT4751M Datasheet HTML 26Page - Qorvo, Inc ACT4751M Datasheet HTML 27Page - Qorvo, Inc Next Button
Zoom Inzoom in Zoom Outzoom out
 23 / 71 page
background image
ACT4751M
AEC-Q100, USB Fast Charger Power IC with 40V Input, 4A, Programmable
Output Voltage and Current
0x09: Configuration byte #2
The register 0x09 is Read / Write type. It configures the device behaviors as described.
Table 13. Register 0x09
Bit #
Bit(s) Name
Def
Description
7
Servo Clock[1]
1
6
Servo Clock[0]
1
See Table 14.
5
Discharge in Servo
1
1: Use discharge resistor to drive VO servo down.
0: Not use discharge resistor in servo.
See Negative Transition with RDIS and Output Discharge Resistor.
4
Discharge at OFF
1
1: Use discharge resistor when main-buck disabled.
0: Not use discharge resistor when main-buck disabled.
See Main-buck Enable Control and Output Discharge Resistor.
3
Main-buck No UVP
0
1: disable main-buck under-voltage protection.
0: use main-buck under-voltage protection.
See UVP selection.
2
Hiccup / Latch-off
0
1: Latch-off action in main-buck.
0: Hiccup action in main-buck.
See Under-Voltage Hiccup and Under-Voltage Latch-off.
Also, see SYNC Error Hiccup and SYNC Error Latch-off.
1
Enable Mini-buck
1
1: enable Mini-buck, automatically start-up Mini-buck.
0: disable Mini-buck, manually start-up Mini-buck.
See V5V, External 5V Supply.
0
Enable AUX LDO
1
1: enable AUX LDO, automatically start-up AUX LDO.
0: disable AUX LDO, manually start-up AUX LDO.
See AUX LDO Enable.
Table 14. Servo Clock [1:0]
Value (bin)
Value (hex)
Servo Clock Period
00
0x00
tW(SERVO) × 1
01
0x01
tW(SERVO) × 2
10
0x02
tW(SERVO) × 4
11
0x03
tW(SERVO) × 8 (default)
ACT4751M Data Sheet, Rev. E, 16-Jul-2020
Subject to change without notice
23
www.qorvo.com



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com