Back Button ADC08D1000EVAL Datasheet HTML 28Page - National Semiconductor (TI) ADC08D1000EVAL Datasheet HTML 29Page - National Semiconductor (TI) ADC08D1000EVAL Datasheet HTML 30Page - National Semiconductor (TI) ADC08D1000EVAL Datasheet HTML 31Page - National Semiconductor (TI) ADC08D1000EVAL Datasheet HTML 32Page - National Semiconductor (TI) ADC08D1000EVAL Datasheet HTML 33Page - National Semiconductor (TI) ADC08D1000EVAL Datasheet HTML 34Page - National Semiconductor (TI) ADC08D1000EVAL Datasheet HTML 35Page - National Semiconductor (TI) ADC08D1000EVAL Datasheet HTML 36Page - National Semiconductor (TI) Next Button
Zoom Inzoom in Zoom Outzoom out
 32 / 37 page
background image
2.0 Applications Information
(Continued)
Input clock amplitudes above those specified in the Electrical
Characteristics Table may result in increased input offset
voltage. This would cause the converter to produce an out-
put code other than the expected 127/128 when both input
pins are at the same potential.
2.4 CONTROL PINS
Six control pins (without the use of the serial interface)
provide a wide range of possibilities in the operation of the
ADC08D1000 and facilitate its use. These control pins pro-
vide Full-Scale Input Range setting, Self Calibration, Calibra-
tion Delay, Output Edge Synchronization choice, LVDS Out-
put Level choice and a Power Down feature.
2.4.1 Full-Scale Input Range Setting
The input full-scale range can be selected to be either 650
mV
P-P or 870 mVP-P, as selected with the FSR control input
(pin 14) in the Normal Mode of operation. In the Extended
Control Mode, the input full-scale range may be set to be
anywhere from 560 mV
P-P to 840 mVP-P. See Section 2.2 for
more information.
2.4.2 Self Calibration
The ADC08D1000 self-calibration must be run to achieve
specified performance. The calibration procedure is run
upon power-up and can be run any time on command. The
calibration procedure is exactly the same whether there is an
input clock present upon power up or if the clock begins
some time after application of power. The CalRun output
indicator is high while a calibration is in progress. Note that
DCLK outputs are not active during a calibration cycle.
2.4.2.1 Power-On Calibration
Power-on calibration begins after a time delay following the
application of power. This time delay is determined by the
setting of CalDly, as described in the Calibration Delay Sec-
tion, below.
The calibration process will be not be performed if the CAL
pin is high at power up. In this case, the calibration cycle will
not begin until the on-command calibration conditions are
met. The ADC08D1000 will function with the CAL pin held
high at power up, but no calibration will be done and perfor-
mance will be impaired. A manual calibration, however, may
be performed after powering up with the CAL pin high. See
On-Command Calibration Section 2.4.2.2.
The internal power-on calibration circuitry comes up in an
unknown logic state. If the input clock is not running at power
up and the power on calibration circuitry is active, it will hold
the analog circuitry in power down and the power consump-
tion will typically be less than 200 mW. The power consump-
tion will be normal after the clock starts.
2.4.2.2 On-Command Calibration
On-command calibration may be run at any time in NOR-
MAL (non-DES) mode only. Do not run a calibration while
operating the ADC in Auto DES Mode.
If the ADC is operating in Auto DES mode and a calibration
cycle is required then the controlling application should bring
the ADC into normal (non DES) mode before an On Com-
mand calibration is initiated. Once calibration has completed,
the ADC can be put back into Auto DES mode.
To initiate an on-command calibration, bring the CAL pin high
for a minimum of 80 input clock cycles after it has been low
for a minimum of 80 input clock cycles. Holding the CAL pin
high upon power up will prevent execution of power-on
calibration until the CAL pin is low for a minimum of 80 input
clock cycles, then brought high for a minimum of another 80
input clock cycles. The calibration cycle will begin 80 input
clock cycles after the CAL pin is thus brought high. The
CalRun signal should be monitored to determine when the
calibration cycle has completed.
The minimum 80 input clock cycle sequences are required to
ensure that random noise does not cause a calibration to
begin when it is not desired. As mentioned in section 1.1.1
for best performance, a self calibration should be performed
20 seconds or more after power up and repeated when the
operating temperature changes significantly, according to
the particular system performance requirements. As can be
seen in the following figures ENOB drops slightly with in-
creasing junction temperature, and a self calibration elimi-
nates the change. In the first example (see Figure 15), a
sample clock of 1GSPS is used to capture a full-scale
749MHz signal at the I-channel input as the junction tem-
perature (T
J) is increased from 65˚C to 125˚C with no inter-
mediate calibration cycles. The vertical line at 125˚C is the
result of an on-command calibration cycle that essentially
eliminates the drop in ENOB. Of course, calibration cycles
can be run more often, at smaller intervals of temperature
change, if system design specifications require it. In the
second example (see Figure 16), the test method is the
same and the I-channel input signal is 249MHz. The varia-
tion in ENOB vs. T
J has a smaller range then the previous
example, and is again removed by an on-command calibra-
tion cycle at the maximum test temperature.
20097457
FIGURE 15. ENOB vs. Junction Temperature, 749MHz
input
www.national.com
32



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com