| Electronic Components Datasheet Search |
|
2030 Datasheet(PDF) 3 Page - Christian Bürkert GmbH & Co. KG |
|
|
|||||||||||||||||||||||||||||
2030 Datasheet(HTML) 3 Page - Christian Bürkert GmbH & Co. KG |
|
3 / 13 page ![]() Type 8026 3 | 13 Visit product website 1. General technical data Note: If the device is mounted in a humid environment or outside, then the maximum voltage allowed is 35 V DC instead of 36 V DC. Product properties Material Make sure the device materials are compatible with the fluid you are using. Further information can be found in chapter “3.1. Bürkert resistApp” on page 6. Further information on the materials can be found in chapter “3.2. Material specifications” on page 6. Non wetted parts Cover Polycarbonate (PC), transparent (opaque on request) Housing Stainless steel 1.4404, PPS Screw Stainless steel 1.4401 (316 (A4)) Grounding terminal and screw Stainless steel 1.4301 (304 (A2)) Display/configuration module PC Menu key PBT Union nut PC Seal EPDM, silicone Fixed connector holder PPS CF30 Fixed connector Nickel-plated brass (stainless steel on request) Wetted parts Sensor armature PVDF Axis and bearing Ceramics (Al 2O3) Paddle wheel PVDF Seal FKM standard (EPDM included, but not mounted) Compatibility Any pipe from DN 20 1.)…DN 400 which is fitted with Bürkert Type S020 Insertion fitting. For the selection of the nominal diameter of the fittings, see data sheet Type S020 . Pipe diameter DN 20 1.)…DN 400 Dimensions Further information can be found in chapter “4. Dimensions” on page 7. Measuring principle Paddle wheel Measuring range • Flow rate: 0.5…75000 l/min (0.13…19813 gpm) • Flow velocity: 0.3…10 m/s Product accessory Display/configuration module Grey dot matrix 128 x 64 with backlighting Performance data Measurement deviation • Teach-in: ± 1 % of the measured value 2.) at teach flow rate value • Standard K factor: ± 2.5 % of the measured value 2.) Linearity ± 0.5 % of full scale 2.) Repeatability ± 0.4 % of the measured value 2.) 4…20 mA output uncertainty ± 1 % of current range Electrical data Operating voltage • 2 or 3 outputs transmitter (2-wire) variant: 14…36 V DC, filtered and regulated • 4 outputs transmitter (3-wire) variant: 12…36 V DC, filtered and regulated Connection to main supply: permanent, through external SELV (Safety Extra Low Voltage) and LPS (Limited Power Source) power supply Power source (not supplied) Limited power source according to UL/EN 62368-1 standards or limited energy circuit according to UL/ EN 61010-1 paragraph 9.4 DC reverse polarity protection Yes Overvoltage protection Yes Current consumption With sensor • ≤ 1 A (with transistors load) • 2 or 3 outputs transmitter (2-wire) variant: ≤ 25 mA (at 14 V DC without transistors load, with current loop) • 4 outputs transmitter (3-wire) variant: ≤ 5 mA (at 12 V DC without transistors load, without current loop) Power consumption Max. 40 W |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |