3 / 19 page

- 3 -
© Andigilog, Inc. 2006
www.andigilog.com
August 2006 - 70A04010
aSC7511
Logic Electrical Characteristics
(TA = 25 °C, VDD = 3.3V unless otherwise noted)
Parameter
Symbol
Conditions
Min
Typ
Max
Units
Input Voltage Logic High
VIH
3V
≤VDD≤3.6V
2.1
V
Input Voltage Logic Low
VIL
3V
≤VDD≤3.6V
0.8
V
Output Voltage Logic Low
( ALERT and THERM )
VOL
VDD=3.6V, IOL= -6mA
0.4
V
Output Low Sink Current
( ALERT and THERM )
IOL
ALERT or THERM
forced to 0.4V
1
mA
Input Leakage Current
IIN
VIN = 0V or 5.5V,
-40°C
≤TA≤+125°C
±1.0
µA
SMBus Output Sink Current
IOL
TA = 25 °C, VOL = 0.6V
6
mA
SMBus Logic Input Current
IIH, IIL
-1
+1
µA
Output Leakage Current
IOH
VOH = VDD = 3.6V
0.1
1
µA
Output Transition Time
tF
CL= 400pF, IOL = -3mA
250
ns
Input Capacitance
CIN
All Digital Inputs
5
pF
Serial Port Timing
(TA = 25 °C, VDD = 3.3V unless otherwise noted, Guaranteed by design, not production tested)
Parameter
Symbol
Min
Typ
Max
Units
SCL Operating Frequency
fSCL
400
kHz
SCL Clock Transition Time
tT:LH , tT:HL
300
ns
SCL Clock Low Period
tLOW
1.3
μs
SCL Clock High Period
tHIGH
0.6
50
μs
Bus free time between a Stop and a new Start Condition
tBUF
1.3
μs
Data in Set-Up to SCL High
tSU:DAT
100
ns
Data Out Stable after SCL Low
tHD:DAT
300
ns
SCL Low Set-up to SDA Low (Repeated Start Condition)
tSU:STA
600
ns
SCL High Hold after SDA Low (Start Condition)
tHD:STA
600
ns
SDA High after SCL High (Stop Condition)
tSU:STO
600
ns
Time in which aSC7511 must be operational after a power-on reset
tPOR
500
ms
tHD:STA
tSU:STO
tSU:DAT
SCL
tBUF
tSU:STA
tT:HL
tT:LH
tLOW
tHIGH
tHD:DAT
SCL
SDA
Data Out
10
10
90
90