| Electronic Components Datasheet Search |
|
PL75-7 Datasheet(PDF) 88 Page - List of Unclassifed Manufacturers |
|
|
|||||||||||||||||||||||||||||
PL75-7 Datasheet(HTML) 88 Page - List of Unclassifed Manufacturers |
|
88 / 141 page ![]() R Trompeter Products Catalog - T21 Military/Aerospace ISO 9001 Registered (800) 982-2629 Fax: (818) 706-1040 www.trompeter.com 88 Electronic systems wiring & cable Triax Cable Triax cable is coax cable with an additional outer copper braid (insu- lated from the signal carrying conductors) that acts as a true shield and protects the enclosed coax conductors. This braid or shield is grounded and passes both ground loop and capacitive field noise currents away from the signal carrying coax, thereby greatly improving the “signal to noise” ratio over standard coax cable. Triax cable is also used in “Driven Shield” applications where the inner conductor and the first braid are driven in parallel at the transmitting end and work against the outer braid which is insulated above ground. The inner braid is left floating at the receiving end, providing a “Fara- day” shield between the inner conductor and outer braid. In this way the cable's distributed capacitance is greatly reduced, thereby reduc- ing cable losses and loading. This application is most effective in high frequency transducer data systems where the distributed capacity in coax cable limits the data accuracy. The two outer braids of the triax cable can be used as a low-impedance (approximately 12 ohms) trans- mission line to carry high-current pulses to low impedance laser lamps or exploding bridge wire (EBW) ordnance systems. Triax cable and connectors completely insulated from the ground are available for these applications. Twinax Cable -Twinax cable is a two-conductor twisted balanced wire line with a spe- cific impedance and a shielding braid around both wires. The twisting of the two balanced-signal-carrying wires cancels any random induced noise voltage pickup, giving protection against any low frequency mag- netic noise passing through the copper braid. Trompeter’s twinax cable design also lowers cable losses by adding two (2) dielectric fillers un- der the braid which separates the braid away from the signal pair, thereby lowering the leakage capacitance to ground. Additionally, the coverage is improved to 90% by using more copper wire in the braid and weaving it tighter. Like triax cable, Trompeter's twinax cable provides protection against ground loops and capacitive fields. Twinax cable usefulness, how- ever, is limited to approximately 15 MHz since it has rather high trans- mission losses above this frequency. Twinax cable and concentric con- nectors are available for low frequency, digital and video distribution systems. Radiated Fields Where strong radiated noise fields exist, such as high powered ra- dar, broadcast stations, power lines, fluorescent lighting, office and industrial machinery, multiple cable runs, etc., the cable con- ductors act as receiving antennas or secondary windings of trans- formers and pick up externally generated noise. At higher frequen- cies, a part of the energy associated with the fluctuating current of charge in a conductor is radiated away from the conductor in the form of electromagnetic radiation. Electromagnetic shields make use of the fact that the electromagnetic radiation must simulta- neously contain electric and magnetic fields in order to propagate independently through space. Therefore, a shield designed to elimi- nate electrostatic fields can be used to neutralize the electric field component of an electromagnetic wave. Consequently the outer con- ductor of a coax cable connected to a ground through a low-imped- ance path will be an effective shield against electromagnetic inter- ference. In high-level RF environments, it is desirable to minimize the RF potentials existing between points on a coax shield. The shield should be grounded at both ends of the cable and at intermediate points along the cable. This multi-point grounding of the shield maintains the RF shielding effectiveness of the cable. If coax cable is used in a radiated interference area, the outer conductor should be grounded as often as possible and wherever feasible in order to remove the radiated interference as soon as possible. If your appli- cation requires that you address both ground loops and radiated interference, you may need to use either twinax or triax cable. A particularly bad source of noise pickup is the induced currents (cross-talk) encountered in large multiple cable installations. Two improved types of cables are used for additional protection against these radiated sources: Source Load RF Interference (Cable acts as antenna) Source Load Magnetic Fields Source Load Cross Talk I N Source Load Triax Cables Provide Additional Shield, Insulated from Signal Carrying Coax I N Triax Driven Shield Load Source Twinax Cable Provides A Shield, Insulated from The Twisted Pair Signal Carrying Conductors Load Source I N |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |