| Electronic Components Datasheet Search |
|
FS6600 Datasheet(PDF) 16 Page - NXP Semiconductors |
|
|
|||||||||||||||||||||||||||||
FS6600 Datasheet(HTML) 16 Page - NXP Semiconductors |
|
16 / 166 page ![]() NXP Semiconductors FS6600 Fail-safe system basis chip with multiple SMPS and LDO 14.2 Main state machine The FS6600 starts when VSUP > VSUP_UVH and WAKE1 or WAKE2 > WAKE12VIH with VBOS first, followed by VPRE, VBOOST and the power-up sequencing from the OTP programming for the remaining regulators if PSYNC pin is pulled up to VBOS. If during the power-up sequence VSUP < VSUP_UVL, the device goes back to Standby mode. When the power up is finished, the main state machine is in Normal_M mode which is the application running mode with all the regulators ON and VSUP_UVL has no effect even if VSUP < VSUP_UVL. See Figure 4 for the minimum operating voltage. The power-up sequence can be synchronized with another PMIC using the PSYNC pin. This synchronization is done in order to stop before or after VPRE is ON and then waiting for PMIC feedback on PSYNC pin before allowing FS6600 to continue its power-up sequence. See Section 27.3 "PSYNC for two FS6600" for more details on PSYNC pin. If the power-up sequence from VPRE ON to NORMAL_M is not completed within 1 second, the device goes back to Standby mode. VPRE restarts when VSUP > VSUP_UVH and WAKE1 or WAKE2 > WAKE12VIH. The device goes to Standby mode by an SPI command from the MCU. If the WD is disabled by the OTP_WD_DIS bit, for an application without MCU, the device goes to Standby mode when both WAKE1 and WAKE 2 = 0. The device goes to Standby mode following the power-down sequence to stop all the regulators in the reverse order of the power-up sequence. VPRE shutdown can be delayed from 250 μs to 32 ms by OTP_VPRE_off_dly bit in case VPRE is supplying an external PMIC to wait its power-down sequence completion. In case of loss of VPRE (VPRE < VPRE_UVL) or loss of VBOS (VBOS < VBOS_UVL), the device stops and goes directly to Standby mode without a power-down sequence. VPRE restarts when VSUP > VSUP_UVH and WAKE1 or WAKE2 > WAKE12VIH. In case of VPRE_FB_OV detection, or TSD detection on a regulator depending on OTP_conf_tsd[5:0] bits configuration, or deep fail-safe request from the fail-safe state machine when DFS = 1, the device stops and goes directly to DEEP-FS mode without power-down sequence. Exit of DEEP-FS mode is only possible by WAKE1 = 0 or after 4 s if the auto retry feature is activated by the OTP_Autorety_en bit. The number of auto retries can be limited to 15 or infinite depending on OTP_Autoretry_infinite bit. VPRE restarts when VSUP > VSUP_UVH and WAKE1 or WAKE2 > WAKE12VIH. 14.3 Fail-safe state machine The fail-safe state machine starts with LBIST execution when VBOS > VBOS_POR. When the LBIST is done, the 8 s timer monitoring the RSTB pin starts and the ABIST1 is automatically executed when all the regulators assigned to ABIST1 have passed their undervoltage threshold. When the ABIST1 is done, RSTB and PGOOD pins are released and the initialization of the device is opened for 256 ms. ABIST1 fail does not prevent RSTB and PGOOD release but maintains FS0B asserted. The first good watchdog refresh closes the INIT_FS. Continuous watchdog refresh is now required. The device waits for SPI command to execute the ABIST2. When the ABIST2 is done and passes, the fault counter must be cleared with the appropriate number of good watchdog refreshes in order to release the FS0B pin per the procedure described in Section 31.8.4 "FS0B release". When FS0B pin is released, the device is ready for application running mode with all the selected monitoring activated. From this point, the FS6600 reacts by asserting the safety pins (PGOOD, RSTB and FS0B) according to its configuration when a fault is detected. The safety pins hierarchical priority is 1-PGOOD, 2-RSTB, 3-FS0B. 14.4 Power sequencing VPRE is the first regulator to start automatically, followed by the BOOST, before the SLOT_0. The other regulators are starting from the OTP power sequencing configuration. Seven slots are available to program the start-up sequence of BUCK1, BUCK 2, BUCK 3, LDO1 and LDO2 regulators. The delay between each slot is FS6600 All information provided in this document is subject to legal disclaimers. © 2024 NXP B.V. All rights reserved. Product data sheet Rev. 3 — 17 July 2024 Document feedback 16 / 166 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |