Back Button FS6600 Datasheet HTML 10Page - NXP Semiconductors FS6600 Datasheet HTML 11Page - NXP Semiconductors FS6600 Datasheet HTML 12Page - NXP Semiconductors FS6600 Datasheet HTML 13Page - NXP Semiconductors FS6600 Datasheet HTML 14Page - NXP Semiconductors FS6600 Datasheet HTML 15Page - NXP Semiconductors FS6600 Datasheet HTML 16Page - NXP Semiconductors FS6600 Datasheet HTML 17Page - NXP Semiconductors FS6600 Datasheet HTML 18Page - NXP Semiconductors Next Button
Zoom Inzoom in Zoom Outzoom out
 14 / 166 page
background image
NXP Semiconductors
FS6600
Fail-safe system basis chip with multiple SMPS and LDO
13 Characteristics
TA = −40 °C to 125 °C, unless otherwise specified. VSUP = VSUP_UVH to 36 V, unless otherwise specified. All voltages referenced to
ground.
Symbol
Parameter
Min
Typ
Max
Unit
Power supply
ISUP_NORMAL
Current in Normal mode, all regulators ON (IOUT = 0)
—
15
25
mA
ISUP_STANDBY
Current in Standby mode, all regulators OFF except VBOS —
5
10
mA
ISUP_OFF1
Current in OFF mode (power-down), TA < 85 °C
—
10
15
μA
ISUP_OFF2
Current in OFF mode (power-down), TA = 125 °C
—
—
25
μA
VSUP_UV7
VSUP undervoltage threshold (7.0 V)
7.2
7.5
7.8
V
VSUP undervoltage threshold high (during power-up and
Vsup rising) OTP_VSUP_CFG = 0
4.7
—
5.1
V
VSUP_UVH
VSUP undervoltage threshold high (during power-up and
Vsup rising) OTP_VSUP_CFG = 1
6.0
—
6.4
V
VSUP undervoltage threshold low (during power-up and
Vsup falling) OTP_VSUP_CFG = 0
4.0
—
4.4
V
VSUP_UVL
VSUP undervoltage threshold low (during power-up and
Vsup falling) OTP_VSUP_CFG = 1
5.3
—
5.7
V
TSUP_UV
VSUP_UV7, VSUP_UVH and VSUP_UVL filtering time
6.0
10
15
μs
Table 6. Electrical characteristics
14 Functional description
The FS6600 device has two independent logic blocks. The main state machine manages the power
management, the Standby mode and the wake-up sources. The fail-safe state machine manages the monitoring
of the power management, the monitoring of the MCU and the monitoring of an external IC.
FS6600
All information provided in this document is subject to legal disclaimers.
© 2024 NXP B.V. All rights reserved.
Product data sheet
Rev. 3 — 17 July 2024
Document feedback
14 / 166



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com