| Electronic Components Datasheet Search |
|
D8254 Datasheet(PDF) 3 Page - Digital Core Design |
|
|
|||||||||||||||||||||||||||||
D8254 Datasheet(HTML) 3 Page - Digital Core Design |
|
3 / 4 page ![]() All trademarks mentioned in this document are trademarks of their respective owners. Copyright 1999-2007 DCD – Digital Core Design. All Rights Reserved. ● ● ● ● ● ● http://www.DigitalCoreDesign.com http://www.dcd.pl been selected by holding CS low. The WR and CLK signals should be synchronous. This is accomplished by using a CLK input signal to the D8254 counters which is a derivative of the system clock source. Another technique is to externally synchronize the WR and CLK input signals. This is done by gating WR with CLK. Data Bus Buffer 8-bit buffer is used to inter- face the D8254 to the system bus. Control Word - The Control Word Register is selected by the Read/Write Logic when ADDR(1:0) = 11. If the CPU then does a write operation to the D8254, the data is stored in the Control Word Register and is interpreted as a Control Word used to define the opera- tion of the Counters. COUNTERS BLOCK DIAGRAM All three Counters (0, 1, 2) are functionally identical and fully independent. Each can work as a 16 bit wide Binary or BCD counter, in one of the six available modes: Interrupt on terminal count Hardware retriggerable One-Shot Rate Generator Square wave mode Software triggered strobe Hardware triggered strobe The internal block diagram of a single counter is shown in Figure below. CRL CRM CE OLL OLM Satus Register Status Latch Ctrl. Word Register Control Unit clkn gaten outn datao(7:0) datai(7:0) The central element of each Counter is CE module - Counting Element – 16 bit pre- settable synchronous down BIN/BCD counter. Status Register, Status Latch – Status register contains actual mode declaration and value of output signal. Latched in Status Latch, after receiving Read-Back Command with STATUS Bit = 0. Control Unit – Controls read/write operation and decrementing of CE. CR M, CR L – Input data registers. When new count is written to counter, the count is written in the CR and later transferred to CE. OL L, OL M – Output data registers. Latched when the suitable Counter Latch Command is sent to the D8254. Control Word - The Control Word Register is selected by the Read/Write Logic when ADDR(1:0) = 11. If the CPU then does a write operation to the D8254, the data is stored in the Control Word Register and is interpreted as a Control Word used to define the opera- tion of the Counters. PERFORMANCE The following table gives a survey about the Core area and performance in the AL- TERA® devices after Place & Route: Device Speed grade Logic Cells Fmax CYCLONE -6 150 MHz CYCLONE 2 -6 166 MHz STRATIX -5 181 MHz STRATIX 2 -3 238 MHz STRATIXGX -5 185 MHz MERCURY -5 135 MHz EXCALIBUR -1 108 MHz APEX II -7 140 MHz APEX20KC -7 129 MHz APEX20KE -1 105 MHz APEX20K -1V 88 MHz ACEX1K -1 99 MHz FLEX10KE -1 102 MHz Core performance in ALTERA® devices |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |