Back Button ACT4752 Datasheet HTML 27Page - Qorvo, Inc ACT4752 Datasheet HTML 28Page - Qorvo, Inc ACT4752 Datasheet HTML 29Page - Qorvo, Inc ACT4752 Datasheet HTML 30Page - Qorvo, Inc ACT4752 Datasheet HTML 31Page - Qorvo, Inc ACT4752 Datasheet HTML 32Page - Qorvo, Inc ACT4752 Datasheet HTML 33Page - Qorvo, Inc ACT4752 Datasheet HTML 34Page - Qorvo, Inc ACT4752 Datasheet HTML 35Page - Qorvo, Inc Next Button
Zoom Inzoom in Zoom Outzoom out
 31 / 71 page
background image
ACT4752
USB Fast Charger Power IC with 40V Input Voltage, 4A, Programmable
Output Voltage and Current
Control Logic
The ACT4752 device integrates a logic block that controls entire behavior of the device in a manner of state-machine
(STM).
At a higher level, the STM consists of nine major status as shown in Table 27.
Table 27. Major States in STM
State
Description
IN
OUT
Normal State
No Power
No power at the VIN pin.
any state
@Power Removed, UVLO, or
OVLO
Bias Ramp
@Power Attached
Bias Ramp
Power at the VIN pin, bias
blocks ramping up.
No Power
@Power Attached
RFREQ Check
@Mini-buck UP
Bias Ready
Bias blocks ready, waiting for
main-buck enable.
PGBIAS = logic-H
RFREQ Check
@PGBIAS↑
Main-buck Ramp
@EN↑
Main-buck Ramp
Main-buck enabled and ramping
up.
PGBIAS = logic-H
Bias Ready
@EN↑
Main-buck ON
@PG↑
Main-buck ON
Main-buck is up and running.
PGBIAS = logic-H,
PG = logic-H
Main-buck Ramp
@PG↑
or
Main-buck Servo
@Servo Complete
Main-buck Servo
@Register Change
Servo
Main-buck is up and running,
changing output voltage or
current target.
PGBIAS = logic-H,
PG = logic-L
Main-buck ON
@Register Change
Main-buck Ramp
@Servo Complete
Protection States
Bias Reset
Critical error in bias blocks,
waiting to reset. See Protection
Level 2.
any Normal State
@Mini-buck OCP,OVP,UVP,
@AUX LDO UVP,
@RFREQ Out of Range,
@Hard TSD
Bias Ramp
@tD(RESET) Time-out
RFREQ Check
Waiting for valid RFREQ. See
RFREQ Protection.
Bias Ramp
@(Mini-buck Up)
Bias Ready
@RFREQ Validated
Main-buck
Shutdown
Main-buck disabled, or in error
to latched-OFF. See Protection
Level 3.
any state EN=H
@iEN
↓
@Main-buck UVP(Latch-off)
@SYNC Input Error Latch-off
@Over-Voltage Protection
@Over-Current Protection
Bias Ready
@Shutdown Completed
Main-buck Error
Main-buck in error to auto-
restart. See Protection Level 4.
any state EN=H
@Main-buck UVP(Hiccup)
@SYNC Input Error Hiccup
@Soft TSD
Main-buck Ramp
@Hiccup Time-out
or
Bias Ready
@iEN
↓
ACT4752 Data Sheet, Rev. A, 16-Jul-2020
Subject to change without notice
31
www.qorvo.com



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com