Back Button ACT4752 Datasheet HTML 51Page - Qorvo, Inc ACT4752 Datasheet HTML 52Page - Qorvo, Inc ACT4752 Datasheet HTML 53Page - Qorvo, Inc ACT4752 Datasheet HTML 54Page - Qorvo, Inc ACT4752 Datasheet HTML 55Page - Qorvo, Inc ACT4752 Datasheet HTML 56Page - Qorvo, Inc ACT4752 Datasheet HTML 57Page - Qorvo, Inc ACT4752 Datasheet HTML 58Page - Qorvo, Inc ACT4752 Datasheet HTML 59Page - Qorvo, Inc Next Button
Zoom Inzoom in Zoom Outzoom out
 55 / 71 page
background image
ACT4752
USB Fast Charger Power IC with 40V Input Voltage, 4A, Programmable
Output Voltage and Current
Main-buck Soft-start into Pre-biased Output
The main-buck supports a start-up operation into a pre-biased output so to avoid huge discharge current from the pre-
biased output capacitor.
As described in Main-buck Soft-start, in a case of normal start-up ("non" pre-biased output), the soft-start function starts
from zero target and the main-buck control loop try to follow the REFIN voltage that is rising by the servo. Here, at the inputs
of the Error Amplifier, the reference is higher than the feedback.
In a case of pre-biased output without this "pre-bias" support, until its reference voltage comes to the pre-biased output
voltage, the feedback is higher than the reference. So a regulator without the "pre-bias" support tries to pull down its pre-
biased output toward the voltage target its reference points. Usually, this results in a huge reverse current flow from its
output capacitor.
The soft-start engine of the ACT4752 device is designed to do nothing until the REFIN voltage comes to the pre-biased
output voltage.
Error Amplifier
The main-buck has one error amplifier to maintain high feedback loop gain. The feedback input voltage at the FB_VO pin
and the reference input voltage at the REFIN pin are compared by the error amplifier and its error output signal is assigned
at the COMP pin.
A compensation network is required between the COMP pin and the ground. See Figure 49 and Main-buck Compensation
Network.
Valley Current Mode Loop Control
The ACT4752 employs a proprietary valley current mode control to regulate the output voltage. The control maintains its
operation at a fixed frequency point for EMI noise sensitive applications. This unique current-mode yields very high loop
gain bandwidth and good stability over wide range of its operating conditions.
Main-buck Switching Options
Forced Continuous Current Operation
The device operates in a forced continuous conduction mode (FCCM). With this FCCM operation, the regulator maintains
its switching frequency to meet the fSW(MAIN) targets. These fSW(MAIN) parameter ensures that its operation frequency do not
interfere with AM radio frequency by staying above the AM band.
Pulse-skip Operation
This function block is not used in this ACT4752 device option. This is a placeholder for other device options
in the ACT475x family. See Ordering Information.
100% Duty Operation
When the PVIN pin voltage is close to the target output voltage VO, the main-buck gets into 100% duty mode by setting the
Reg0B[7] bit.
Without this 100% duty mode (disabled), the device is designed to output a minimum OFF period at each cycle, even
though its internal PWM comparator continuously demands more ON duty. This minimum OFF pulse helps to stay at its
target switching frequency but it is not desirable when the input voltage is very close to the output as the output voltage
starts dropping.
When the 100% duty mode is enabled, the device stops forcing the minimum OFF pulse and the high-side FET maintains
ON for multiple cycles without turning OFF as long as the PWM comparator indicates low feedback voltage. This 100% duty
operation helps bringing the output voltage close to the input.
When keeping the high-side FET ON for a long time period, the bootstrap capacitor voltage becomes lower as a high-
side gate driver consumes power from the bootstrap capacitor. To maintain a proper operation of the high-side FET, the
bootstrap capacitor needs to be recharged occasionally. This refresh action happens at every eight cycles. This means that,
at a worst case, its operation switching frequency becomes one eighth (1/8 = 12.5%) of the target setting.
The Reg03[3] bit is set logic-H to indicate that the regulator is in 100% duty operation. When using this 100% duty
operation, consider to increase amount of output capacitance by monitoring the output voltage.
ACT4752 Data Sheet, Rev. A, 16-Jul-2020
Subject to change without notice
55
www.qorvo.com



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com