Back Button ACT88411 Datasheet HTML 2Page - Qorvo, Inc ACT88411 Datasheet HTML 3Page - Qorvo, Inc ACT88411 Datasheet HTML 4Page - Qorvo, Inc ACT88411 Datasheet HTML 5Page - Qorvo, Inc ACT88411 Datasheet HTML 6Page - Qorvo, Inc ACT88411 Datasheet HTML 7Page - Qorvo, Inc ACT88411 Datasheet HTML 8Page - Qorvo, Inc ACT88411 Datasheet HTML 9Page - Qorvo, Inc ACT88411 Datasheet HTML 10Page - Qorvo, Inc  
Zoom Inzoom in Zoom Outzoom out
 8 / 10 page
background image
ACT85411
Power Loss Protection with Power Management
ACT85411 Datasheet Brief, Rev. A March 2025
8 of 10
www.qorvo.com
®
© 2025 Qorvo US, Inc. – All Rights Reserved
PIN DESCRIPTIONS
PIN
NAME
DESCRIPTION
1, 2, 48, 66, 67, 68
VIN
Power Supply Input to the eFuse. Connect a 0.1µF capacitor between VIN and PGND close to the IC.
3
COMP
Compensation input pin for the PLP Buck converter (active in supplement mode).
4, 17, 23, 35, 43, 64,
69, 70
VBUS
Output for bypass mode, in-rush, and eFuse functionality. VBUS is also the input voltage bus for the
downstream regulators.
5
VSPL
Supplement buck circuit output pin (Boost input pin). It is isolated from VBUS by the internal blocking FET.
6
GPIO5
GPIO5 Pin
7, 54
PGND_PLP
PLP Power Ground. Connect to large ground plane on PCB.
8, 55
SW_PLP
Power loss protection Buck/Boost switching node. Place an inductor between VSPL & SW_PLP.
9, 56
STR
Storage capacitor input/output. Connect the storage capacitors to STR. (Minimum 100µF).
10
HSB
High side bootstrap pin. Connect a 47nF capacitor between HSB & SW_PLP pins.
11
GPIO2
GPIO2 Pin
12, 13
PGND1
Buck1 power ground pin. Connect to large ground plane on PCB
14, 15, 16, 57
SW1
Switch pin for HV Buck1 regulator
18
VBOOT1
Bootstrap voltage for Buck1 regulator. Connect a 0.1µF capacitor between VBOOT1 and SW1 pins.
19
VFB1
Output and feedback pin for Buck1 regulator.
20
GPIO1
GPIO1 Pin
21
VFB2
Output and feedback pin for Buck2 regulator.
22
VBOOT2
Bootstrap voltage for Buck2 regulator. Connect a 0.1µF capacitor between VBOOT2 and SW2 pins.
24, 25, 26 58
SW2
Switch pin for HV Buck2 regulator.
27, 28
PGND2
Buck2 power ground pin. Connect to large ground plane on PCB
29
GPIO6
GPIO6 Pin
30, 59
VLDO
LDO output pin. Place 2.2uF or larger ceramic between this pin and AGND.
31, 60
VAUX
VAUX Input pin. This is used as input voltage to the LDO.
32, 61
VCC
Output and feedback pin for VCC Buck regulator. Connect a 10µF capacitor between VCC and AGND.
33, 62
AGND
Analog GND Pin. Connect to clean ground on the PCB.
34, 63
SW5
Switch pin for VCC Mini-Buck regulator. Connect an inductor between SW5 and VCC pins.
36, 65
VBBST
Output and feedback pin for Buck-Boost regulator. Connect a 10µF capacitor between VBBST and PGND
37
SW4
Second Switch pin for Buck-Boost regulator. Connect an inductor between SW4 and SW3 pins.
38
VBOOT4
Second Bootstrap pin for Buck-Boost regulator. Connect a 0.1µF capacitor between VBOOT4 and SW4.
39, 40
PGND34
Power Ground connection for the Buck-Boost regulator and the mini-buck regulator.
41
SW3
Switch pin for Buck-Boost regulator. Connect an inductor between SW3 and SW4 pins.
42
VBOOT3
Bootstrap pin for Buck-Boost regulator. Connect a 0.1µF capacitor between VBOOT3 and SW3.
44
SCL
I2C clock input. Needs an external pull up resistor.
45
SDA
I2C data input /output pin. Needs an external pull up resistor.
46
GPIO4
GPIO4 Pin
47
GPIO3
GPIO3 Pin
49
EN /
nDISCHG
Enable pin for the eFuse and PLP circuit. When EN = 0, the eFuse blocks output from the input and the
supplement mode is turned on. The PLI output goes low when EN = 0 to indicate supplement mode.
50
PLI
Power Loss Indicator, Open-Drain Output for VIN. PLI goes high when the eFuse is turned on and goes low
when the IC enters supplement mode. PLI is referenced to AGND.
51
SS
Soft Start Input. Place a capacitor from SS to VSS to control the eFuse startup voltage slew rate.
52
PG_STR
Storage Okay Output Pin. The output of the health monitoring circuit indicates the health monitoring status
and if the STR output voltage is okay (higher than the STR_OK threshold).
Exposed Pad
VBUS
Tie to top layer VBUS plane. All VBUS pins should be directly connected to the exposed pad on the top layer.



Html Pages

1 2 3 4 5 6 7 8 9 10


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com