| Electronic Components Datasheet Search |
|
AMC80 Datasheet(PDF) 10 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
AMC80 Datasheet(HTML) 10 Page - Texas Instruments |
|
10 / 31 page ![]() Temperature Sensor IN0 Addr=20h Interrupt Masking and Interrupt Control InterfaceandControl AMC80 CH0 CH6 Analog Inputs GPI(CI) INT_IN BTI A0/TEST_OUT SDA SCL A1 A2 CH1 CH2 CH3 CH4 CH5 INT RST_OUTOS / Interrupt Outputs Serial Bus Interface 10-Bit Delta-Sigma ADC FanSpeed Counter FAN1 FAN2 NTEST_INRESET_IN / Digital Inputs and Outputs Interrupt Status Registers ValueRAM IN1 Addr=21h IN2 Addr=22h IN3 Addr=23h IN4 Addr=24h IN5 Addr=25h IN6 Addr=26h Temperature Addr=27h Fan1 Addr=28h Fan2 Addr=29h UpperLimit LowerLimit Watchdog UpperLimit LowerLimit UpperLimit LowerLimit UpperLimit LowerLimit UpperLimit LowerLimit UpperLimit LowerLimit UpperLimit LowerLimit OS Hysteresis UpperLimit UpperLimit Hot Hysteresis Fan Tachometer PulseInputs GPO AMC80 SBOS559B – MAY 2011 – REVISED OCTOBER 2015 www.ti.com 7 Detailed Description 7.1 Overview The AMC80 provides seven analog inputs, a temperature sensor, a delta-sigma analog-to-digital converter (ADC), and a variety of inputs and outputs on a single chip. A two-wire SMBus interface is also provided. The AMC80 can continuously perform power-supply, temperature, and fan monitoring for a variety of applications. The AMC80 is fully pin- and software-compatible with the LM96080 and LM80. 7.2 Functional Block Diagram 7.3 Feature Description 7.3.1 Block Level Description The AMC80 continuously converts analog inputs to 10-bit resolution using a 2.5-mV least significant bit (LSB) with a default input range of 0 V to 2.56 V, or a 6-mV LSB with a programmable input range of 0 V to V+. The analog inputs (CH0 to CH6) are intended for connection to the several power supplies present in any typical system. Temperature can be converted to a 9-bit or 12-bit resolution with either 0.5°C or 0.0625°C LSB, respectively. The FAN1 and FAN2 inputs can be programmed to accept either a fan failure indicator or tachometer signals. Fan failure signals can be programmed to be either active high or active low. Fan inputs measure the period of tachometer pulses from the the fans, providing a higher count for lower fan speeds. The fan inputs are digital inputs with transition levels according to the Digital Inputs section of the Electrical Characteristics table. Full-scale fan counts are 255 (8-bit counter), which represent a stopped or very slow fan. Nominal speeds, based on a count of 153, are programmable from 1100 RPM to 8800 RPM. Signal conditioning circuitry is included to accommodate slow rise and fall times. The AMC80 provides a number of internal registers: • Configuration Register: Provides control and configuration. • Interrupt Status Registers: Two registers that provide the status of each interrupt alarm. • Interrupt Mask Registers: Allows masking of individual interrupt sources, as well as separate masking for 10 Submit Documentation Feedback Copyright © 2011–2015, Texas Instruments Incorporated Product Folder Links: AMC80 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |