Back Button TC3097-8 Datasheet HTML 5Page - List of Unclassifed Manufacturers TC3097-8 Datasheet HTML 6Page - List of Unclassifed Manufacturers TC3097-8 Datasheet HTML 7Page - List of Unclassifed Manufacturers TC3097-8 Datasheet HTML 8Page - List of Unclassifed Manufacturers TC3097-8 Datasheet HTML 9Page - List of Unclassifed Manufacturers TC3097-8 Datasheet HTML 10Page - List of Unclassifed Manufacturers TC3097-8 Datasheet HTML 11Page - List of Unclassifed Manufacturers TC3097-8 Datasheet HTML 12Page - List of Unclassifed Manufacturers TC3097-8 Datasheet HTML 13Page - List of Unclassifed Manufacturers Next Button
Zoom Inzoom in Zoom Outzoom out
 9 / 35 page
background image
TC3097-8
Preliminary Data Sheet
COUNT CLEAR - 0
CC(X) = 0
Datain(X) = DIPresent(X)
RESET
COLLISION COUNT IDLE - 1
Datain(X) = DIPresent(X)
TEN(X) = Idle &
DIPresent(X)=Idle
TEN(X)=Active +
DIPresent(X)=Active
WATCH FOR COLLISION - 2
Datain(X) = DIPresent(X)
Enable Tw5
DIPresent(X)=Idle &
TEN(X)=Idle &
/COLN,/ANYXN=Idle
{[TEN(X)=Active &
DIPresent(X)=Idle] +
[TEN(X)=Idle &
DIPresent(X)=Active]} &
Tw5Done &
/COLN,/ANYXN=Idle
COLLISION COUNT INCREMENT - 3
TEN(X)=Idle &
DIPresent(X)=Idle &
CC(X) < 31 & /Tw6Done
CC(X) = CC(X) + 1
Datain(X) = DIPresent(X)
EnableTw6
[/COLN=Active +
/ANYXN=Active +
TEN(X)=Active] &
DIPresent(X)=Active
PARTITION WAIT - 4
Datain(X) = Idle
CC(X) >= 31 +
[TEN(X)=Active &
DIPresent(X)=Active &
Tw6Done]
PARTITION HOLD - 5
Datain(X) = Idle
TEN(X)=Idle &
DIPresent(X)=Idle
PARTITION COLLISION WATCH - 6
Datain(X) = Idle
EnableTw5
TEN(X)=Active +
DIPresent(X)=Active
TEN(X)=Idle &
DIPresent(X)=Idle &
/COLN,/ANYXN=Idle
[/COLN=Active +
ANYXN=Active +
TEN(X)=Active] &
DIPresent(X)=Active
WAIT TO RESTORE PORT - 7
Datain(X) = Idle
CC(X) = 0
{[TEN(X)=Active & DIPresent(x)=Idle] +
[TEN(X)=Idle & DIPresent(X)=Active]} &
Tw5Done & /COLN, /ANYXN=Idle
TEN(X)=Idle & DIPresent(X)=Idle
Figure 2. Partition State Diagram for TP Port X
Confidential.
9/35
July 21. 2003
Copyright © 2003, IC Plus Corp.
TC3097-8-DS-R24



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com