39 / 100 page ![]() www.national.com 38 5.5 Power Down/Interrupt The Power Down and Interrupt functions are multiplexed on pin 18 and pin 44 of the device. By default, this pin func- tions as a power down input and the interrupt function is disabled. Setting bit 0 (INT_OE) of MICR (11h) will config- ure the pin as an active low interrupt output. Ports A and B can be powered down individually, using the separate PWRDOWN_INT_A and PWRDOWN_INT_B pins. 5.5.1 Power Down Control Mode The PWRDOWN_INT pins can be asserted low to put the device in a Power Down mode. This is equivalent to setting bit 11 (Power Down) in the Basic Mode Control Register, BMCR (00h). An external control signal can be used to drive the pin low, overcoming the weak internal pull-up resistor. Alternatively, the device can be configured to ini- tialize into a Power Down state by use of an external pull- down resistor on the PWRDOWN_INT pin. Since the device will still respond to management register accesses, setting the INT_OE bit in the MICR register will disable the PWRDOWN_INT input, allowing the device to exit the Power Down state. 5.5.2 Interrupt Mechanisms Since each port has a separate interrupt pin, the interrupts can be connected individually or may be combined in a wired-OR fashion. If the interrupts share a single connec- tion, each port status should be checked following an inter- rupt. The interrupt function is controlled via register access. All interrupt sources are disabled by default. Setting bit 1 (INTEN) of MICR (11h) will enable interrupts to be output, dependent on the interrupt mask set in the lower byte of the MISR (12h). The PWRDOWN_INT pin is asynchro- nously asserted low when an interrupt condition occurs. The source of the interrupt can be determined by reading the upper byte of the MISR. One or more bits in the MISR will be set, denoting all currently pending interrupts. Read- ing of the MISR clears ALL pending interrupts. Example: To generate an interrupt on a change of link sta- tus or on a change of energy detect power state, the steps would be: — Write 0003h to MICR to set INTEN and INT_OE — Write 0060h to MISR to set ED_INT_EN and LINK_INT_EN — Monitor PWRDOWN_INT pin When PWRDOWN_INT pin asserts low, the user would read the MISR register to see if the ED_INT or LINK_INT bits are set, i.e. which source caused the interrupt. After reading the MISR, the interrupt bits should clear and the PWRDOWN_INT pin will deassert. 5.6 Energy Detect Mode When Energy Detect is enabled and there is no activity on the cable, the DP83849C will remain in a low power mode while monitoring the transmission line. Activity on the line will cause the DP83849C to go through a normal power up sequence. Regardless of cable activity, the DP83849C will occasionally wake up the transmitter to put ED pulses on the line, but will otherwise draw as little power as possible. Energy detect functionality is controlled via register Energy Detect Control (EDCR), address 1Dh. 5.7 Link Diagnostic Capabilities The DP83849C contains several system diagnostic capa- bilities for evaluating link quality and detecting potential cabling faults in Twisted Pair cabling. Software configura- tion is available through the Link Diagnostics Registers - Page 2 which can be selected via Page Select Register (PAGESEL), address 13h. These capabilities include: — Linked Cable Status — Link Quality Monitor — TDR (Time Domain Reflectometry) Cable Diagnostics 5.7.1 Linked Cable Status In an active connection with a valid link status, the following diagnostic capabilities are available: — Polarity reversal — Cable swap (MDI vs MDIX) detection — 100Mb Cable Length Estimation — Frequency offset relative to link partner — Cable Signal Quality Estimation 5.7.1.1 Polarity Reversal The DP83849C detects polarity reversal by detecting nega- tive link pulses. The Polarity indication is available in bit 12 of the PHYSTS (10h) or bit 4 of the 10BTSCR (1Ah). Inverted polarity indicates the positive and negative con- ductors in the receive pair are swapped. Since polarity is corrected by the receiver, this does not necessarily indicate a functional problem in the cable. Since the polarity indication is dependent on link pulses from the link partner, polarity indication is only valid in 10Mb modes of operation, or in 100Mb Auto-Negotiated mode. Polarity indication is not available in 100Mb forced mode of operation or in a parallel detected 100Mb mode. 5.7.1.2 Cable Swap Indication As part of Auto-Negotiation, the DP83849C has the ability (using Auto-MDIX) to automatically detect a cable with swapped MDI pairs and select the appropriate pairs for transmitting and receiving data. Normal operation is termed MDI, while crossed operation is MDIX. The MDIX status can be read from bit 14 of the PHYSTS (10h). |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |