Back Button DP83848-HT Datasheet HTML 28Page - Texas Instruments DP83848-HT Datasheet HTML 29Page - Texas Instruments DP83848-HT Datasheet HTML 30Page - Texas Instruments DP83848-HT Datasheet HTML 31Page - Texas Instruments DP83848-HT Datasheet HTML 32Page - Texas Instruments DP83848-HT Datasheet HTML 33Page - Texas Instruments DP83848-HT Datasheet HTML 34Page - Texas Instruments DP83848-HT Datasheet HTML 35Page - Texas Instruments DP83848-HT Datasheet HTML 36Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 32 / 81 page
background image
DP83848-HT
SLLSEJ7 – FEBRUARY 2015
www.ti.com
BLW results from the interaction between the low frequency components of a transmitted bit stream and the
frequency response of the AC coupling components within the transmission system. If the low frequency content
of the digital bit stream goes below the low frequency pole of the AC coupling transformers then the droop
characteristics of the transformers will dominate resulting in potentially serious BLW.
The digital oscilloscope plot provided in Figure 34 illustrates the severity of the BLW event that can theoretically
be generated during 100BASE-TX packet transmission. This event consists of approximately 800 mV of DC
offset for a period of 120
μs. Left uncompensated, events such as this can cause packet loss.
8.3.2.3 Signal Detect
The signal detect function of the DP83848 is incorporated to meet the specifications mandated by the ANSI FDDI
TP-PMD Standard as well as the IEEE 802.3 100BASE-TX Standard for both voltage thresholds and timing
parameters.
Note that the reception of normal 10BASE-T link pulses and fast link pulses per IEEE 802.3u auto-negotiation by
the 100BASE-TX receiver do not cause the DP83848 to assert signal detect.
8.3.2.4 MLT-3 to NRZI Decoder
The DP83848 decodes the MLT-3 information from the Digital Adaptive Equalizer block to binary NRZI data.
8.3.2.5 NRZI to NRZ
In a typical application, the NRZI to NRZ decoder is required in order to present NRZ formatted data to the
descrambler.
8.3.2.6 Serial to Parallel
The 100BASE-TX receiver includes a serial to parallel converter which supplies 5-bit wide data symbols to the
PCS Rx state machine.
8.3.2.7 Descrambler
A serial descrambler is used to de-scramble the received NRZ data. The descrambler has to generate an
identical data scrambling sequence (N) in order to recover the original unscrambled data (UD) from the
scrambled data (SD) as represented in the equations:
SD = (UD
⊕ N)
(1)
UD = (SD
⊕ N)
(2)
Synchronization of the descrambler to the original scrambling sequence (N) is achieved based on the knowledge
that the incoming scrambled data stream consists of scrambled IDLE data. After the descrambler has recognized
12 consecutive IDLE code-groups, where an unscrambled IDLE code-group in 5B NRZ is equal to five
consecutive ones (11111), it will synchronize to the receive data stream and generate unscrambled data in the
form of unaligned 5B code-groups.
In order to maintain synchronization, the descrambler must continuously monitor the validity of the unscrambled
data that it generates. To ensure this, a line state monitor and a hold timer are used to constantly monitor the
synchronization status. Upon synchronization of the descrambler the hold timer starts a 722
μs countdown. Upon
detection of sufficient IDLE code-groups (58 bit times) within the 722
μs period, the hold timer will reset and
begin a new countdown. This monitoring operation will continue indefinitely given a properly operating network
connection with good signal integrity. If the line state monitor does not recognize sufficient unscrambled IDLE
code-groups within the 722
μs period, the entire descrambler will be forced out of the current state of
synchronization and reset in order to reacquire synchronization.
8.3.2.8 Code-Group Alignment
The code-group alignment module operates on unaligned 5-bit data from the descrambler (or, if the descrambler
is bypassed, directly from the NRZI/NRZ decoder) and converts it into 5B code-group data (5 bits). Code-group
alignment occurs after the J/K code-group pair is detected. Once the J/K code-group pair (11000 10001) is
detected, subsequent data is aligned on a fixed boundary.
32
Submit Documentation Feedback
Copyright © 2015, Texas Instruments Incorporated
Product Folder Links: DP83848-HT



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com