Back Button DP83848-HT Datasheet HTML 31Page - Texas Instruments DP83848-HT Datasheet HTML 32Page - Texas Instruments DP83848-HT Datasheet HTML 33Page - Texas Instruments DP83848-HT Datasheet HTML 34Page - Texas Instruments DP83848-HT Datasheet HTML 35Page - Texas Instruments DP83848-HT Datasheet HTML 36Page - Texas Instruments DP83848-HT Datasheet HTML 37Page - Texas Instruments DP83848-HT Datasheet HTML 38Page - Texas Instruments DP83848-HT Datasheet HTML 39Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 35 / 81 page
background image
DP83848-HT
www.ti.com
SLLSEJ7 – FEBRUARY 2015
Once disabled by the Jabber function, the transmitter stays disabled for the entire time that the ENDEC module's
internal transmit enable is asserted. This signal has to be deasserted for approximately 500 ms (the “unjab” time)
before the Jabber function re-enables the transmit outputs.
The Jabber function is only relevant in 10BASE-T mode.
8.3.3.7 Automatic Link Polarity Detection and Correction
The DP83848's 10BASE-T transceiver module incorporates an automatic link polarity detection circuit. When
three consecutive inverted link pulses are received, bad polarity is reported.
A polarity reversal can be caused by a wiring error at either end of the cable, usually at the main distribution
frame (MDF) or patch panel in the wiring closet.
The bad polarity condition is latched in the 10BTSCR register. The DP83848's 10BASE-T transceiver module
corrects for this error internally and will continue to decode received data correctly. This eliminates the need to
correct the wiring error immediately.
8.3.3.8 Transmit and Receive Filtering
External 10BASE-T filters are not required when using the DP83848, as the required signal conditioning is
integrated into the device.
Only isolation transformers and impedance matching resistors are required for the 10BASE-T transmit and
receive interface. The internal transmit filtering ensures that all the harmonics in the transmit signal are
attenuated by at least 30 dB.
8.3.3.9 Transmitter
The encoder begins operation when the transmit enable input (TX_EN) goes high and converts NRZ data to
preemphasized Manchester data for the transceiver. For the duration of TX_EN, the serialized transmit data
(TXD) is encoded for the transmit-driver pair (PMD Output Pair). TXD must be valid on the rising edge of transmit
clock (TX_CLK). Transmission ends when TX_EN deasserts. The last transition is always positive; it occurs at
the center of the bit cell if the last bit is a one, or at the end of the bit cell if the last bit is a zero.
8.3.3.10 Receiver
The decoder detects the end of a frame when no additional mid-bit transitions are detected. Within one and a
half bit times after the last bit, carrier sense is de-asserted. Receive clock stays active for five more bit times
after CRS goes low, to guarantee the receive timings of the controller.
8.3.4 Reset Operation
The DP83848 includes an internal power-on reset (POR) function and does not need to be explicitly reset for
normal operation after power up. If required during normal operation, the device can be reset by a hardware or
software reset.
8.3.4.1 Hardware Reset
A hardware reset is accomplished by applying a low pulse (TTL level), with a duration of at least 1
μs, to the
RESET_N. This will reset the device such that all registers will be reinitialized to default values and the hardware
configuration values will be re-latched into the device (similar to the power-up/reset operation).
8.3.4.2 Software Reset
A software reset is accomplished by setting the reset bit (bit 15) of the basic mode control register (BMCR). The
period from the point in time when the reset bit is set to the point in time when software reset has concluded is
approximately 1
μs.
The software reset will reset the device such that all registers will be reset to default values and the hardware
configuration values will be maintained. Software driver code must wait 3
μs following a software reset before
allowing further serial MII operations with the DP83848.
Copyright © 2015, Texas Instruments Incorporated
Submit Documentation Feedback
35
Product Folder Links: DP83848-HT



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com