Back Button INA226 Datasheet HTML 9Page - Texas Instruments INA226 Datasheet HTML 10Page - Texas Instruments INA226 Datasheet HTML 11Page - Texas Instruments INA226 Datasheet HTML 12Page - Texas Instruments INA226 Datasheet HTML 13Page - Texas Instruments INA226 Datasheet HTML 14Page - Texas Instruments INA226 Datasheet HTML 15Page - Texas Instruments INA226 Datasheet HTML 16Page - Texas Instruments INA226 Datasheet HTML 17Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 13 / 40 page
background image
measured shunt voltage to determine if the measurements has exceeded the programmed limit. The AFF, bit
4 of the Mask/Enable Register, asserts high any time the measured voltage exceeds the value programmed
into the Alert Limit Register. In addition to the AFF being asserted, the Alert pin is asserted based on the Alert
Polarity Bit (APOL, bit 1 of the Mask/Enable Register). If the Alert Latch is enabled, the AFF and Alert pin remain
asserted until either the Configuration Register (00h) is written to or the Mask/Enable Register is read.
The Bus Voltage alert functions compare the measured bus voltage to the Alert Limit Register following every
bus voltage conversion and assert the AFF bit and Alert pin if the limit threshold is exceeded.
The Power Over-Limit alert function is also compared to the calculated power value following every bus voltage
measurement conversion and asserts the AFF bit and Alert pin if the limit threshold is exceeded.
6.4 Device Functional Modes
6.4.1 Averaging and Conversion Time Considerations
The INA226 device offers programmable conversion times (tCT) for both the shunt voltage and bus voltage
measurements. The conversion times for these measurements can be selected from as fast as 140 μs to as long
as 8.244 ms. The conversion time settings, along with the programmable averaging mode, allow the device to be
configured to optimize the available timing requirements in a given application. For example, if a system requires
that data be read every 5ms, the device can be configured with the conversion times set to 588 μs for both shunt
and bus voltage measurements and the averaging mode set to 4. This configuration results in the data updating
approximately every 4.7ms. The device can also be configured with a different conversion time setting for the
shunt and bus voltage measurements. This type of approach is common in applications where the bus voltage
tends to be relatively stable. This situation can allow for the time focused on the bus voltage measurement to
be reduced relative to the shunt voltage measurement. The shunt voltage conversion time can be set to 4.156
ms with the bus voltage conversion time set to 588 μs, with the averaging mode set to 1. This configuration also
results in data updating approximately every 4.7 ms.
There are trade-offs associated with the settings for conversion time and the averaging mode used. The
averaging feature can significantly improve the measurement accuracy by effectively filtering the signal. This
approach allows the device to reduce any noise in the measurement that can be caused by noise coupling
into the signal. A greater number of averages enables the device to be more effective in reducing the noise
component of the measurement.
The conversion times selected can also have an impact on the measurement accuracy. Figure 6-2 shows
multiple conversion times to illustrate the impact of noise on the measurement. to achieve the highest accuracy
measurement possible, use a combination of the longest allowable conversion times and highest number of
averages, based on the timing requirements of the system.
Figure 6-2. Noise vs Conversion Time
www.ti.com
INA226
SBOS547B – JUNE 2011 – REVISED SEPTEMBER 2024
Copyright © 2024 Texas Instruments Incorporated
Submit Document Feedback
13
Product Folder Links: INA226



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com