THVD1500DR Datasheet(PDF) 17 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
THVD1500DR Datasheet(HTML) 17 Page - Texas Instruments |
|
17 / 30 page ![]() 22 20 18 16 14 12 10 8 6 4 2 0 Time (µs) 0 5 10 15 20 25 30 35 40 0.5-kV Surge 10-kV ESD 4-kV EFT 2.2 2.0 1.8 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0 Time (µs) 0 5 10 15 20 25 30 35 40 0.5-kV Surge 6-kV Surge 3.0 2.8 2.6 2.4 R (C) R (D) C (S) High-Voltage Pulse Generator Device Under Test 40 35 30 25 20 15 10 5 0 Time (ns) 0 50 100 150 200 250 300 10-kV IEC 10-kV HBM 330 Ω (1.5 kΩ) 150 pF (100 pF) 50 M (1 M) 17 THVD1500 www.ti.com SLLSEY4A – JULY 2017 – REVISED NOVEMBER 2018 Product Folder Links: THVD1500 Submit Documentation Feedback Copyright © 2017–2018, Texas Instruments Incorporated Typical Application (continued) 9.2.1.5 Transient Protection The bus pins of the THVD1500 transceiver family include on-chip ESD protection against ±16-kV HBM and ±8- kV IEC 61000-4-2 contact discharge. The International Electrotechnical Commission (IEC) ESD test is far more severe than the HBM ESD test. The 50% higher charge capacitance, C(S), and 78% lower discharge resistance, R(D), of the IEC model produce significantly higher discharge currents than the HBM model. Figure 19. HBM and IEC ESD Models and Currents in Comparison (HBM Values in Parenthesis) The on-chip implementation of IEC ESD protection significantly increases the robustness of equipment. Common discharge events occur because of human contact with connectors and cables. Designers may choose to implement protection against longer duration transients, typically referred to as surge transients. EFTs are generally caused by relay-contact bounce or the interruption of inductive loads. Surge transients often result from lightning strikes (direct strike or an indirect strike which induce voltages and currents), or the switching of power systems, including load changes and short circuit switching. These transients are often encountered in industrial environments, such as factory automation and power-grid systems. Figure 20 compares the pulse-power of the EFT and surge transients with the power caused by an IEC ESD transient. The left hand diagram shows the relative pulse-power for a 0.5-kV surge transient and 4-kV EFT transient, both of which dwarf the 10-kV ESD transient visible in the lower-left corner. 500-V surge transients are representative of events that may occur in factory environments in industrial and process automations. The right hand diagram shows the pulse-power of a 6-kV surge transient, relative to the same 0.5-kV surge transient. 6-kV surge transients are most likely to occur in power generation and power-grid systems. Figure 20. Power Comparison of ESD, EFT, and Surge Transients |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |