| Electronic Components Datasheet Search |
|
AD4084BBCZ Datasheet(PDF) 23 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD4084BBCZ Datasheet(HTML) 23 Page - Analog Devices |
|
23 / 94 page ![]() Data Sheet AD4084 THEORY OF OPERATION analog.com Rev. 0 | 23 of 94 that if VDD11 is not present, the part will be held in a power-on reset (POR) state, and all AD4084 registers reset to their default state after the supply has been reestablished. More details on the POR circuitry can be found in the Power-On Reset (POR) Monitor section. The VDD33 rail is supplied with an external 3.3V supply. The VDD33 supply can be removed to further reduce power (see the Power Saving Operating Modes section), only analog circuity is held in reset, and the register content remains unaffected. Refer to Table 1 for the applicable input voltage tolerance for each supply rail. As illustrated in the example of Figure 40, external voltage sources are applied to VDD11 and IOVDD pins. Figure 40. Externally Sourced Supply Configuration POWER-ON RESET (POR) MONITOR The AD4084 power supply monitoring circuits inhibit the converter functions and reset the configuration memory when supply con- ditions are outside the specified operating limits. This function ensures each device is in a deterministic state after power-up. The power-on function is constructed from two independent voltage monitors, the first measuring the core 1.1V supply and a second measuring the voltage at the reference input pin (REFIN). Each monitor has its own comparator output that is used to decouple the analog and digital block resets as shown in Figure 41. Figure 41. Simplified Diagram of POR Circuit The core VDD (1.1V) supply monitor compares the VDD11 supply voltage against a preset threshold of 0.93V. If the supply voltage falls to less than this threshold, a reset signal, POR_D, asserts. The digital logic reset signal, DIG_RESET, is defined as the logical combination of the POR_D signal and (logical AND) the compliment of the SPI software reset function. When either the POR_D signal (VDD11 < 0.93V) or the SW RESET signal is asserted, the internal digital circuitry is held in reset. When cleared, the contents of the configuration registers are restored to the factory default settings. The reference monitor compares the input voltage at REFIN against a preset threshold of 2.7V. As illustrated in Figure 41, power for the reference monitor circuit is supplied from the VDD33 supply. However, it is important to note that a reference voltage below 2.6V will cause the part to stop outputting conversion data results. To recover the conversion process, the reference voltage needs to be brought to 2.87V. For correct operation of the monitor circuit, the VDD33 supply must be applied to the AD4084 within the specified tolerance of 3.3V ± 5% before the reference source is enabled. Assuming the device is operating within the specified supply conditions, a reference voltage less than 2.7V results in the assertion of an internal reset signal, POR_A. The POR_A signal and (logical AND) the DIG_RESET signal are combined to produce a reset (ANA_RESET) for the analog circuit blocks including the ADC core, ADC timer, reference buffer, and so forth. If this reset signal is asserted, the analog blocks are placed in an inactive state, and the converter functionality is disabled. This event is indicated with a value of 1 in the POR_ANA_FLAG bit from the Device Status Register (Address 0x14). The state of the event detection is persistent until a Logic 1 is written to the POR_ANA_FLAG bit to clear the detection state. POWER SUPPLY SEQUENCE Table 10 specifies the recommended supply sequences for both internal and external generation of 1.1V supply rails (IOVDD and VDD11). Both methods are shown in Figure 42 and Figure 43, where the supplies that must be provided to the AD4084 are highlighted in blue, including the REFIN voltage. In both cases, the AD4084 requires that the supplies are applied in ascending voltage order. The design must also ensure that voltage is applied at the analog inputs (IN+ and IN−) and reference input (REFIN) concurrently with, or immediately following, the VDD33 supply. Failing in providing REFIN reference voltage on power up will result in no ADC conversions at the output of the ADC, and continue to do so until REFIN voltage is provided. Note that test pattern described in the Data Interface Test Functions section will not work in the previously mentioned case when a voltage reference is not provided at the power up. However, if reference voltage was provided at power up and then removed the test pattern will still work and output the correct data. As described in the Power-On Reset (POR) Monitor section, the voltage at the reference input pin must only be applied once VDD33 is within the specified supply tolerance to avoid undesired behavior. Therefore, if the selected voltage reference does not provide an enable pin, it is strongly rec- ommended to design the reference circuit to power up after VDD33. After reset or Power-On Reset there is 300us required before part can be accessed, this is to assure part has all the initialization procedures done. If this condition is not met, NOT_READY_ERR bit will be asserted of the INTERFACE_STATUS_A (0x11). The configuration SPI inputs, CS, SCLK, and SDI, are protected with clamps to the VDD33 supply rail to allow the inputs to swing |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |