Application Information
MAX3222/3232 Datasheet Rev. 0.1 , Sept. 2005
Page 7of 7
Anasys Semiconductor, Inc.
Capacitor Selection
The capacitor type used for C1–C4 is not critical for proper operation; polarized or non-polarized
capacitors can be used. The charge pump requires 0.1µF capacitors for 3.3V operation. Increasing the
capacitor values (e.g., by a factor of 2) reduces ripple on the transmitter outputs and slightly reduces
power consumption. C2, C3, and C4 can be increased without changing C1’s value. When using the
minimum required capacitor values, make sure the capacitor value does not degrade excessively with
temperature. If in doubt, use capacitors with a larger nominal value. The capacitor’s equivalent series
resistance (ESR), which usually rises at low temperatures, influences the amount of ripple on V+ and
V- output voltages.
Power-Supply Decoupling
In most circumstances, a 0.1µF VCC bypass capacitor is adequate. In applications sensitive to
power-supply noise, use a capacitor of the same value as charge pump capacitor C1. Connect bypass
capacitors as close to the IC as possible.
Operation Down to 2.7V
Transmitter outputs meet EIA/TIA-562 levels of ±3.7V with supply voltages as low as 2.7V.
Transmitter Outputs Recovering from Shutdown
When MAX3222E’s two transmitter outputs were recovering from shutdown mode, the two
transmitter outputs are shown going to opposite RS-232 levels (one transmitter input is high; the other
is low) as they become active. Each transmitter is loaded with 3K resistor in parallel with 2500pF. The
transmitter outputs display no ringing or undesirable transients as they come out of shutdown. Note
that the transmitters are enabled only when the magnitude of V- exceeds approximately -3.0V.
Interconnection with 3V and 5V Logic
The MAX3222E/MAX3232E can directly interface with various 3V and 5V logic families, including
ACT and HCT CMOS.