SSD1805 Series
Rev 1.1
P 33/52
Jun 2004
Solomon Systech
OTP Example program
Find the OTP offset:
Hardware reset by sending an active low reset pulse to RES pin
0X2F \\ turn on the internal voltage booster & output op-amp buffer.
0XA2
\\ Set Biasing ratio
0XA9
\\ 1/9 for 68/64 MUX mode
0X62
0X81
\\Set target gain and contrast.
0X20
\\ contrast = 20 Hex.
0X24
\\ IR4 =>
\\ Set target display contents
0x00
\\ set start column address at 0000 binary for lower nibble
0X10
\\ set start column address at 0000 binary for upper nibble
0XB0
\\ set page address at page 0
0xAF
\\ display on
OTP offset calculation… target OTP offset value is +6
OTP programming:
Hardware reset by sending an active low reset pulse to RES pin
Connect a external VOUT (14.5V~15.5V)
0X82
\\ Set OTP offset value to +6 (0110)
0X06
\\ 0000 X3X2X1X0 , where X3X2X1X0 is the OTP offset value
0X83
\\ Send the OTP programming command.
Wait at least 2 seconds for programming wait time.
Verify the result:
After OTP programming, procedure 2 to 5 are repeated for inspection of the contrast on the panel.
9.24 Set Multiplex Ratio
This command switches default multiplex ratio to any multiplex mode from 2 to the maximum multiplex ratio
(POR value), including the icon line.
Max. MUX ratio:68 for 68 MUX mode
65 for 64 MUX mode including icon line
55 for 54 MUX mode including icon line
33 for 32 MUX mode including icon line
The chip pins ROW0 - ROW67 will be switched to corresponding COM signal output, see Table 12 on Page
35 for examples with and without 8 lines display offset for different MUX. It should be noted that after
changing the display multiplex ratio, the bias ratio need to be adjusted to make display contrast consistent.
9.25 Set Bias Ratio
Except the 1/4 bias, all other available bias ratios could be selected using this command plus the “Set LCD
Bias” command. For detail setting values and POR default, please refer to the extended command table,
Table 9 on Page 26.
9.26 Set Temperature Coefficient (TC) Value
One out of 4 different temperature coefficient settings is selected by this command in order to match various
liquid crystal temperature grades. Please refer to the extended command table, Table 9 on Page 26, for
detailed TC values.
9.27 Modify Oscillator Frequency
The oscillator frequency can be fine tuned by applying this command. Since the oscillator frequency will be
affected by some other factors, this command is not recommended for general usage. Please contact
Solomon Systech application engineers for more detail explanation on this command.