8 / 14 page

&
DALSA INC.: Phone: 519-886-6000 Fax: 519-886-8023
03-36-00166-06
ISO 9001
DALSA EUROPE: Phone: +49-8142-46770 Fax: +49-8142-467746
www.dalsa.com
IL-P3
Line Scan Sensors
For product information and updates visit www.dalsa.com
10µW/cm
2
100µW/cm
2
25µW/cm
2
100
0
20
40
60
80
Integration Time (ms)
1.0
0.8
0.6
0.4
0.2
Output vs. Integration Time
(@700nm)
Wavelength (nm)
0
5
1000
800
600
400 500
700
900
10
15
25
40
30
35
45
20
50
Responsivity
Figure 2. Performance Measurements
Symbol
Description
Unit
Min.
Rec.
Max.
tCR
Period of CRx clocks
t1
Integration time (PR disabled)
t2
Integration time (PR enabled)
t3
TCK to first valid pixel
pixels
24
24
t4
Overclock pixels
pixels
0
2
t5
CRLAST rising edge to CR2 falling edge
ns
-0.25tCR
0
0.25tCR
t6
TCK high overlap with CR1 high
ns
200
200
t7
TCK falling edge to CR1 falling edge
ns
2
t8
CRLAST rising to RST rising edge
ns
-0.25tCR
0.5tCR - t11
0.5tCR - t11
t9
RST falling edge to CRLAST falling edge
ns
0
0
0.5tCR-t11
t10
RST pulse width (FWHM)
1
ns
3.5
5
0.25tCR
t11
CR rise and fall time
ns
1
2
0.25tCR
Notes:
1.
Full Width Half Maximum
Table 10. IL-P3 Timing Parameters