16 / 51 page ![]() M58LW032D 16/51 the Status Register. See the section on the Status Register for details on the definitions of the Status Register bits. During the Block Protect operation the memory will only accept the Read Status Register command. All other commands will be ignored. Typical Block Protection times are given in Table 9. The Block Protection bits are non-volatile, once set they remain set through reset and power- down/power-up. They are cleared by a Blocks Un- protect command. See Appendix C, Figure 20, Block Protect Flow- chart and Pseudo Code, for a suggested flowchart on using the Block Protect command. Blocks Unprotect Command. The Blocks Un- protect command is used to unprotect all of the blocks. Two Bus Write cycles are required to issue the Blocks Unprotect command; the second Bus Write cycle starts the Program/Erase Controller. Once the command is issued subsequent Bus Read operations read the Status Register. See the section on the Status Register for details on the definitions of the Status Register bits. During the Block Unprotect operation the memory will only accept the Read Status Register com- mand. All other commands will be ignored. Typical Block Protection times are given in Table 9. See Appendix C, Figure 21, Block Unprotect Flow- chart and Pseudo Code, for a suggested flowchart on using the Block Unprotect command. Protection Register Program Command. The Protection Register Program command is used to Program the 64 bit user segment of the Protection Register. Two write cycles are required to issue the Protection Register Program command. s The first bus cycle sets up the Protection Register Program command. s The second latches the Address and the Data to be written to the Protection Register and starts the Program/Erase Controller. Read operations output the Status Register con- tent after the programming has started. The user-programmable segment can be locked by programming bit 1 of the Protection Register Lock location to ‘0’ (see Table 7 and x for Word- wide and Byte-wide protection addressing). Bit 0 of the Protection Register Lock location locks the factory programmed segment and is programmed to ‘0’ in the factory. The locking of the Protection Register is not reversible, once the lock bits are programmed no further changes can be made to the values stored in the Protection Register, see Figure 6, Protection Register Memory Map. At- tempting to program a previously protected Pro- tection Register will result in a Status Register error. The Protection Register Program cannot be sus- pended. See Appendix C, Figure 22, Protection Register Program Flowchart and Pseudo Code, for the flowchart for using the Protection Register Program command. Configure STS Command. The Configure STS command is used to configure the Status/(Ready/Busy) pin. After power-up or re- set the STS pin is configured in Ready/Busy mode. The pin can be configured in Status mode using the Configure STS command (refer to Sta- tus/(Ready/Busy) section for more details. Two write cycles are required to issue the Config- ure STS command. s The first bus cycle sets up the Configure STS command. s The second specifies one of the four possible configurations (refer to Table 5, Configuration Codes): – Ready/Busy mode – Pulse on Erase complete mode – Pulse on Program complete mode – Pulse on Erase or Program complete mode The device will not accept the Configure STS com- mand while the Program/Erase controller is busy or during Program/Erase Suspend. When STS pin is pulsing it remains Low for a typical time of 250ns. Any invalid Configuration Code will set an error in the Status Register. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |