46 / 48 page ![]() E2E/E2E2 E2E/E2E2 46 Environment Water Resistivity Do not use the Proximity Sensor underwater, outdoors, or in the rain. Operating Environment Be sure to use the Proximity Sensor within its operating ambient temperature range and do not use the Proximity Sensor outdoors so that its reliability and life expectancy can be maintained. Although the Proximity Sensor is water resistive, a cover to protect the Prox- imity Sensor from water or water soluble machining oil is recom- mended so that its reliability and life expectancy can be maintained. Do not use the Proximity Sensor in an environment with chemical gas (e.g., strong alkaline or acid gasses including nitric, chromic, and concentrated sulfuric acid gases). Connecting Load to AC/DC 2-wire Sensor Refer to the following before using AC or DC 2-wire Proximity Sen- sors. Surge Protection Although the Proximity Sensor has a surge absorption circuit, if there is any machine that has a large surge current (e.g., a motor or welding machine) near the Proximity Sensor, connect a surge ab- sorber to the machine. Leakage Current When the Proximity Sensor is OFF, the Proximity Sensor has leak- age current. Refer to pages 17 and 21 Leakage Current Character- istics. In this case, the load is imposed with a small voltage and the load may not be reset. Before using the Proximity Sensor, make sure that this voltage is less than the load reset voltage. The AC 2-wire Proximity Sensor cannot be connected to any card-lift-off relay (e.g., the G2A) because contact vibration of the relay will be caused by the leakage current and the life of the relay will be short- ened. Countermeasures Against Leakage Current AC 2-wire Models Connect a bleeder resistor as the bypass for the leakage current so that the current flowing into the load will be less than the load reset current. As shown in the following diagram, connect the bleeder resistor so that the current flowing into the Proximity Sensor will be 10 mA mini- mum and the residual voltage imposed on the load will be less than the load reset voltage. Load Bleeder resistor R VAC power supply VS Refer to the following to calculate the bleeder resistance and the al- lowable power of the bleeder resistor. R x VS/(10 – I) (kΩ) P > VS2/R (mW) P: The allowable power of the bleeder resistor. (The actual power capacity of the bleeder resistor must be at least a few times as large as the allowable power of the bleeder resistor.) I: Load current (mA) The following resistors are recommended. 100 VAC (supply voltage): A resistor with a resistance of 10 k Ω max- imum and an allowable power of 3 W minimum 200 VAC (supply voltage): A resistor with a resistance of 20 k Ω max- imum and an allowable power of 10 W minimum If these resistors generate excessive heat, use a resistor with a re- sistance of 10 k Ω maximum and an allowable power of 5 W mini- mum at 100 VAC and a resistor with a resistance of 20 k Ω maximum and an allowable power of 10 W minimum at 200 VAC instead. DC 2-wire Models Connect a bleeder resistor as the bypass for the leakage current so that the current flowing into the load will be less than the load reset current. Load Bleeder resistor R Refer to the following to calculate the bleeder resistance and the al- lowable power of the bleeder resistor. R x VS/(iR – iOFF) (kΩ) P > VS2/R (mW) P: The allowable power of the bleeder resistor. (The actual power capacity of the bleeder resistor must be at least a few times as large as the allowable power of the bleeder resistor.) iR: Leakage current of Sensors (mA) iOFF: Release current of load (mA) The following resistors are recommended. 12 VDC (supply voltage): A resistor with a resistance of 15 k Ω maxi- mum and an allowable power of 450 mW minimum 24 VDC (supply voltage): A resistor with a resistance of 30 k Ω maxi- mum and an allowable power of 0.1 W minimum Inrush Current A load that has a large inrush current (e.g., a lamp or motor) will damage the Proximity Sensor, in which case connect the load to the Proximity Sensor through a relay. Connection to a PLC Required Conditions Connection to a PLC is possible if the specifications of the PLC and the Proximity Sensor satisfy the following conditions. (The mean- ings of the symbols are given below.) 1. The ON voltage of the PLC and the the residual voltage of the Proximity Sensor must satisfy the following. VON x VCC – VR 2. The OFF current of the PLC and the the leakage current of the Proximity Sensor must satisfy the following. IOFF y Ileak (If the OFF current is not listed in the specifications, take it to be 1.3 mA.) 3. The ON current of the PLC and the the control output (IOUT) of the Proximity Sensor must satisfy the following. IOUT(min) x ION x IOUT(max) The ON current of the PLC will vary, however, with the power supply voltage and the input impedance used as shown in the following equation. ION = VCC – VR – VPC)/RIN |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |