| Electronic Components Datasheet Search |
|
E2E Datasheet(PDF) 47 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
E2E Datasheet(HTML) 47 Page - Omron Electronics LLC |
|
47 / 48 page ![]() E2E/E2E2 E2E/E2E2 47 Example In this example, the above conditions are checked for when the PLC model is the C00H-ID212, the Proximity Sensor model is the E2E-X7D1-N, and the power supply voltage is 24 V. 1. VON (14.4) x VCC (20.4 V) – VR (3 V) = 17.4 V : OK 2. IOFF (1.3 mA) y Ileak (0.8 mA) : OK 3. ION = [VCC (20.4 V) – VR (3 V) – VPC (4 V)]/RIN (3 kΩ) [ 4.5 mA Therefore, IOUT(min) (3 mA) x ION (4.5 mA) : OK VON: ON voltage of PLC (14.4 V) ION: ON current of PLC (typ. 7 mA) IOFF: OFF current of PLC (1.3 mA) RIN: Input impedance of PLC (3 kΩ) VPC: Internal residual voltage of PLC (4 V) VR: Output residual voltage of Proximity Sensor (3 V) Ileak: Leakage current of Proximity Sensor (0.8 mA) IOUT: Control output of Proximity Sensor (3 to 100 mA) VCC: Power supply voltage (PLC: 20.4 to 26.4 V) The values in parentheses are for the following PLC model and Proximity Sensor model. PLC: C200H-ID212 Proximity Sensor: E2E-X7D1-N Precautions for AC/DC 2-wire Proximity Sensors in Operation Connection Model Connection type Method Description DC 2-wire AND (serial connection) Load Correct The Sensors connected together must satisfy the following conditions. VS – N x VR y Load operating voltage N: No. of Sensors VR: Residual voltage of each Sensor VS: Supply voltage If each Proximity Sensor is not supplied with the rated voltage and current, the indicator will not be lit properly or unnecessary pulses may be output for approximately 1 ms. OR (parallel connection) Load Correct The Sensors connected together must satisfy the following conditions. N x i x Load operating voltage N: No. of Sensors i: Leakage current of each Sensor If the MY Relay, which operates at 24 VDC, is used as a load for example, a maximum of four Proximity Sensors can be connected to the load. AC 2-wire AND (serial connection) Load Load Load Vs y 100 V Incorrect Correct If 100 or 200 VAC is imposed on the Proximity Sensors, VL (i.e., the voltage imposed on the load) will be obtained from the following. VL = VS – (residual voltage x no. of Proximity Sensors) (V) Therefore, if VL is lower than the load operating voltage, the load will not operate. A maximum of three Proximity Sensors can be connected in series provided that the supply voltage is 100 V minimum. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |