| Electronic Components Datasheet Search |
|
DVC1000 Datasheet(PDF) 5 Page - LEM |
|
|
|||||||||||||||||||||||||||||
DVC1000 Datasheet(HTML) 5 Page - LEM |
|
5 / 13 page ![]() Page 5/13 17January2023/Version 3 LEM reserves the right to carry out modifications on its transducers, in order to improve them. LEM International SA Route du Nant-d’Avril, 152 1217 Meyrin www.lem.com DVC 1000 Insulation coordination Parameter Symbol Unit ≤ Value Comment RMS voltage for AC insulation test at 50 Hz U d kV 4.26 Type test: 1mn Routine test: 10s (100 % tested in prod.) Both tests according to IEC 62497-1 Impulse withstand voltage 1.2/50 μs U Ni kV 7.84 According to IEC 62497-1 Partial discharge RMS test voltage (q m < 10 pC) U t V 1650 According to 61800-5-1 Case material - - V0 According to UL 94 Comparative tracking index CTI 600 Between primary and secondary Maximum RMS insulation voltage 1) 1000 600 300 CAT I & II CAT III CAT IV Clearance d CI mm 9.0 Shortest distance through air Creepage distance d Cp mm 9.0 Shortest path along device body Application example RMS voltage line-to-neutral V 600 Basic insulation according to IEC 61010-1, CAT III, PD2 Application example RMS voltage line-to-neutral V 300 Reinforced insulation according to IEC 61010-1, CAT III, PD2 Application example System voltage RMS V 600 Basic insulation according to IEC 61800-5-1, IEC 62109-1 CAT III, PD2 Application example System voltage RMS V 600 Reinforced insulation according to IEC 61800-5-1, IEC 62109-1 CAT III, PD2 Application example Rated insulation RMS voltage V 600 Basic insulation according to IEC 62497-1 CAT III, PD2 Application example Rated insulation RMS voltage U Nm V 500 Reinforced insulation according to IEC 62497-1, CAT III, PD2 Operating voltage V 1000 Insulation according to UL 508, CAT II, PD2 Between primary and ground Clearance d CI mm 9.8 Shortest distance through air Creepage distance d Cp mm 9.8 Shortest path along device body Application example Rated insulation RMS voltage V 300 Reinforced insulation according to IEC 61010-1, CAT III, PD2 Between secondary and ground Clearance d CI mm 8.7 Shortest distance through air Creepage distance d Cp mm 8.7 Shortest path along device body Application example Rated insulation RMS voltage V 300 Reinforced insulation according to IEC 61010-1, CAT III, PD2 Note: 1) Electronic board limitation. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |