| Electronic Components Datasheet Search |
|
DVC1000 Datasheet(PDF) 11 Page - LEM |
|
|
|||||||||||||||||||||||||||||
DVC1000 Datasheet(HTML) 11 Page - LEM |
|
11 / 13 page ![]() Page 11/13 17January2023/Version 3 LEM reserves the right to carry out modifications on its transducers, in order to improve them. LEM International SA Route du Nant-d’Avril, 152 1217 Meyrin www.lem.com DVC 1000 Electrical offset referred to primary K O L: Overload factor Figure 14: voltage cycle used to measure the electrical offset (transducer supplied) Using the voltage cycle shown in previous figure, the electrical offset voltage U O E is the residual output referred to primary when the input voltage is zero. The temperature variation U O T of the electrical offset voltage U O E is the variation of the electrical offset from 25 °C to the considered temperature. Sensitivity and linearity To measure sensitivity and linearity, the primary voltage (DC) is cycled from 0 to U P, then to −UP and back to 0 (equally spaced U P/10 steps). The sensitivity S is defined as the slope of the linear regression line for a cycle between ±U P N. The linearity error ε L is the maximum positive or negative difference between the measured points and the linear regression line, expressed in % of U P N. Delay times The delay time t D 10 @ 10 % and the delay time tD 90 @ 90 % with respect to the primary are shown in the next figure. Both slightly depend on the primary voltage dv/dt. They are measured at nominal voltage. I S t D 10 t D 90 t 90 % 10 % 100 % U P U Figure 15: delay time t D 10 @ 10 % and delay time tD 90 @ 90 %. Simplified transducer model The static model of the transducer with current output at temperature T A is: I S = S ⋅ UP ⋅ (1 + ε) In which (referred to primary): ε ⋅ U P = UO E + UO T + εS ⋅ UP + εS T ⋅ UP + εL(UP max) ⋅ UP max U P : primary voltage (V) U P max : maximum primary voltage applied to the transducer (V) I S : secondary current (A) S : sensitivity of the transducer TCS : temperature coefficient of S T A : ambient operating temperature (°C) U O E : electrical offset voltage (V) U O T : temperature variation of U O E (V) ε S : sensitivity error at 25 °C ε S T : thermal drift of S ε L(UP max) : linearity error for U P max This model is valid for primary voltage U P between −UP max and +U P max only. This is the absolute maximum error. As all errors are independent, a more realistic way to calculate the error would be to use the following formula: Total error referred to primary The total error ε tot is the error at ±UP N, relative to the rated value U P N. It includes all errors mentioned above ● the electrical offset U O E ● the sensitivity error ε S ● the linearity error ε L (to UP N). Figure 13: Total error ε tot Terms and definitions 2 1 N i i εε = = ∑ -0,02 0,00 0,02 0,04 0,06 0,08 0,10 0,12 -1 -0,5 0 0,5 1 UP / (KOL · UP N) with KOL = 1 .. 10 Total error ℇtot at UC = ... V and TA = 25 °C aver. + 3σ UO E (max) / UP N -1 0 1 1 2 3 4 5 Step Primary voltage cycle P (3) P (5) O E 2 UU U + = ( ) ( ) ( ) O O E O E 25 C T U T U TU = − ° |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |