13 / 21 page ![]() Alarms The DS3234 contains two time-of-day/date alarms. Alarm 1 can be set by writing to registers 07h to 0Ah. Alarm 2 can be set by writing to registers 0Bh to 0Dh. The alarms can be programmed (by the alarm enable and INTCN bits of the control register) to activate the INT/SQW output on an alarm match condition. Bit 7 of each of the time-of- day/date alarm registers are mask bits (Table 2). When all the mask bits for each alarm are logic 0, an alarm only occurs when the values in the timekeeping registers match the corresponding values stored in the time-of- day/date alarm registers. The alarms can also be pro- grammed to repeat every second, minute, hour, day, or date. Table 2 shows the possible settings. Configurations not listed in the table will result in illogical operations. The DY/DT bits (bit 6 of the alarm day/date registers) control whether the alarm value stored in bits 0 to 5 of that register reflects the day of the week or the date of the month. If DY/DT is written to logic 0, the alarm will be the result of a match with date of the month. If DY/DT is written to logic 1, the alarm will be the result of a match with day of the week. When the RTC register values match alarm register set- tings, the corresponding Alarm Flag ‘A1F’ or ‘A2F’ bit is set to logic 1. If the corresponding Alarm Interrupt Enable ‘A1IE’ or ‘A2IE’ is also set to logic 1 and the INTCN bit is set to logic 1, the alarm condition activates the INT/SQW signal. The match is tested on the once- per-second update of the time and date registers. Table 2. Alarm Mask Bits ALARM 1 REGISTER MASK BITS (BIT 7) DY/DT A1M4 A1M3 A1M2 A1M1 ALARM RATE X 1 1 1 1 Alarm once per second X 1 1 1 0 Alarm when seconds match X 1 1 0 0 Alarm when minutes and seconds match X 1 0 0 0 Alarm when hours, minutes, and seconds match 0 0 0 0 0 Alarm when date, hours, minutes, and seconds match 1 0 0 0 0 Alarm when day, hours, minutes, and seconds match ALARM 2 REGISTER MASK BITS (BIT 7) DY/DT A2M4 A2M3 A2M2 ALARM RATE X 1 1 1 Alarm once per minute (00 seconds of every minute) X 1 1 0 Alarm when minutes match X 1 0 0 Alarm when hours and minutes match 0 0 0 0 Alarm when date, hours, and minutes match 1 0 0 0 Alarm when day, hours, and minutes match Extremely Accurate SPI Bus RTC with Integrated Crystal and SRAM ____________________________________________________________________ 13 |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |