| Electronic Components Datasheet Search |
|
CS5463 Datasheet(PDF) 29 Page - Cirrus Logic |
|
|
|||||||||||||||||||||||||||||
CS5463 Datasheet(HTML) 29 Page - Cirrus Logic |
|
29 / 46 page ![]() CS5463 DS678F2 29 6.1.10 Power Offset Register ( Poff ) Address: 14 Default = 0x000000 Power Offset (Poff) is added to the instantaneous power being accumulated in the Pactive register, and can be used to offset contributions to the energy result that are caused by undesirable sources of energy that are in- herent in the system. The value is represented in two's complement notation and in the range of -1.0 ≤ Poff < 1.0, with the binary point to the right of the MSB. 6.1.11 Status Register and Mask Register ( Status , Mask ) Address: 15 (Status Register); 26 (Mask Register) Default = 0x800001 (Status Register), 0x000000 (Mask Register) The Status Register indicates status within the chip. In normal operation, writing a '1' to a bit will cause the bit to reset. Writing a '0' to a bit will not change it’s current state. The Mask Register is used to control the activation of the INT pin. Placing a logic '1' in a Mask bit will allow the corresponding bit in the Status Register to activate the INT pin when the status bit is asserted. DRDY Data Ready. During conversions, this bit will indicate the end of computation cycles. For cali- brations, this bit indicates the end of a calibration sequence. CRDY Conversion Ready. Indicates a new conversion is ready. This will occur at the output word rate. IOR Current Out of Range. Set when the Instantaneous Current Register overflows. VOR Voltage Out of Range. Set when the Instantaneous Voltage Register overflows. IROR IRMS Out of Range. Set when the IRMS Register overflows. VROR VRMS Out of Range. Set when the VRMS Register overflows. EOR Energy Out of Range. Set when PACTIVE overflows. IFAULT Indicates a current fault has occurred. See Section 5.6 Sag and Fault Detect Feature on page 19. VSAG Indicates a voltage sag has occurred. See Section 5.6 Sag and Fault Detect Feature on page 19. TUP Temperature Updated. Indicates the Temperature Register has updated. TOD Modulator oscillation detected on the temperature channel. Set when the modulator oscillates due to an input above full scale. VOD (IOD) Modulator oscillation detected on the voltage (current) channel. Set when the modulator oscil- MSB LSB -(20)2-1 2-2 2-3 2-4 2-5 2-6 2-7 ..... 2-17 2-18 2-19 2-20 2-21 2-22 2-23 23 22 21 20 19 18 17 16 DRDY CRDY IOR VOR 15 14 13 12 11 10 9 8 IROR VROR EOR IFAULT VSAG 7 654 32 10 TUP TOD VOD IOD LSD FUP IC |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |