Back Button LT1912 Datasheet HTML 9Page - Linear Technology LT1912 Datasheet HTML 10Page - Linear Technology LT1912 Datasheet HTML 11Page - Linear Technology LT1912 Datasheet HTML 12Page - Linear Technology LT1912 Datasheet HTML 13Page - Linear Technology LT1912 Datasheet HTML 14Page - Linear Technology LT1912 Datasheet HTML 15Page - Linear Technology LT1912 Datasheet HTML 16Page - Linear Technology LT1912 Datasheet HTML 17Page - Linear Technology Next Button
Zoom Inzoom in Zoom Outzoom out
 13 / 24 page
background image
LT1912
13
1912f
practical approach is to start with one of the circuits in
this data sheet that is similar to your application and tune
the compensation network to optimize the performance.
Stability should then be checked across all operating
conditions, including load current, input voltage and
temperature. The LT1375 data sheet contains a more
thorough discussion of loop compensation and describes
how to test the stability using a transient load. Figure 2
shows an equivalent circuit for the LT1912 control loop.
The error amplifier is a transconductance amplifier with
finite output impedance. The power section, consisting of
the modulator, power switch and inductor, is modeled as
a transconductance amplifier generating an output cur-
rent proportional to the voltage at the VC pin. Note that
the output capacitor integrates this current, and that the
capacitor on the VC pin (CC) integrates the error ampli-
fier output current, resulting in two poles in the loop. In
most cases a zero is required and comes from either the
output capacitor ESR or from a resistor RC in series with
CC. This simple model works well as long as the value
of the inductor is not too high and the loop crossover
frequency is much lower than the switching frequency.
A phase lead capacitor (CPL) across the feedback divider
may improve the transient response. Figure 3 shows the
transient response when the load current is stepped from
500mA to 1500mA and back to 500mA.
BOOST and BIAS Pin Considerations
Capacitor C3 and the internal boost Schottky diode (see
the Block Diagram) are used to generate a boost volt-
age that is higher than the input voltage. In most cases
a 0.22μF capacitor will work well. Figure 2 shows three
ways to arrange the boost circuit. The BOOST pin must be
more than 2.3V above the SW pin for best efficiency. For
outputs of 3V and above, the standard circuit (Figure 4a)
is best. For outputs between 2.8V and 3V, use a 1μF boost
capacitor. A 2.5V output presents a special case because it
is marginally adequate to support the boosted drive stage
while using the internal boost diode. For reliable BOOST pin
operation with 2.5V outputs use a good external Schottky
diode (such as the ON Semi MBR0540), and a 1μF boost
capacitor (see Figure 4b). For lower output voltages the
boost diode can be tied to the input (Figure 4c), or to
another supply greater than 2.8V. Tying BD to VIN reduces
the maximum input voltage to 30V. The circuit in Figure 4a
is more efficient because the BOOST pin current and BD
pin quiescent current comes from a lower voltage source.
You must also be sure that the maximum voltage ratings
of the BOOST and BD pins are not exceeded.
The minimum operating voltage of an LT1912 application
is limited by the minimum input voltage (3.6V) and by the
maximum duty cycle as outlined in a previous section. For
proper startup, the minimum input voltage is also limited
by the boost circuit. If the input voltage is ramped slowly,
0.8V
SW
VC
gm =
420μmho
GND
3Meg
LT1912
1912 F02
R1
OUTPUT
ESR
CF
CC
RC
ERROR
AMPLIFIER
FB
R2
C1
C1
CURRENT MODE
POWER STAGE
gm = 3.5mho
+
POLYMER
OR
TANTALUM
CERAMIC
CPL
Figure 2. Model for Loop Response
APPLICATIONS INFORMATION
Figure 3. Transient Load Response of the LT1912 Front Page
Application as the Load Current is Stepped from 500mA to
1500mA. VOUT = 3.3V
1912 F03
IL
0.5A/DIV
VOUT
100mV/DIV
10μs/DIV
VIN = 12V; FRONT PAGE APPLICATION



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com