STAR1000
Document Number: 38-05714 Rev. *C
Page 5 of 21
Absolute Maximum Ratings
Table 3. Absolute Maximum Ratings STAR1000
Characteristics
Limits
Units
Remarks
Min
Max
Any supply voltage
-0.5
+7
V
R
Voltage on any input terminal
-0.5
Vdd + 0.5
V
Operating temperature
0
+60
°C
Temperature range confirmed by
evaluation testing.
Storage temperature
-10
+60
°C
Not longer than 1 hour. Temperature range
confirmed by evaluation testing.
Sensor soldering temperature
NA
125
°C
Hand soldering only. The sensor’s
temperature may not rise above this limit.
Please read the Soldering and Handling
Conditions on page 18 for more
information.
Table 4. Absolute Maximum Ratings STAR1000BK7 and STAR1000SP
Characteristics
Limits
Units
Remarks
Min
Max
Any supply voltage
-0.5
+7
V
Voltage on any input terminal
-0.5
Vdd + 0.5
V
Operating temperature
-40
+85
°C
Temperature range confirmed by
evaluation testing.
Storage temperature
-40
+85
°C
Temperature range confirmed by
evaluation testing.
-40
+120
Maximum 1 hour.
Sensor soldering
temperature
NA
125
°C
Hand soldering only. The sensor’s
temperature may not rise above this limit.
Please read the Soldering and Handling
Conditions on page 18 for more
information.
Table 5. DC Operating Conditions
Symbol
Parameter
Limits
Units
Min
Typ
Max
VDDA
Analog supply of the image core.
5
V
VDDD
Digital supply of the image core.
5
V
VDD_ADC_ANA
Analog supply of the ADC circuitry.
5
V
VDD_ADC_DIG
Digital supply of the ADC circuitry.
5
V
VDD_DIG_OUT
Power supply of ADC digital output stage.
5
V
VRES
Reset level for RESET signal.
5
V
VREF
Reset level for RESET_DS signal.
4
5
V
[+] Feedback