19 / 30 page ![]() CS2000-OTP DS758F1 19 5.7 Mode Pin Functionality 5.7.1 M1 and M0 Mode Pin Functionality M[1:0] determine the functional mode of the device and select both the default User Defined Ratio and the set of modal parameters. The modal parameters are RModSel[1:0], AuxOutSrc[1:0], LockClk[1:0], and FracNSrc. By modifying one or more of the modal parameters between the 4 sets, different functional con- figurations can be achieved. However, global parameters are fixed and the same value will be applied to each functional configuration. Figure 17 on page 22 provides a summary of all parameters used by the device. 5.7.2 M2 Mode Pin Functionality M2 usage is mapped to one of the optional special functions via the M2Config[2:0] global parameter. De- pending on what M2 is mapped to, it will either act as an output enable/disable pin or override certain mod- al parameters. Figure 16 summarizes the available options and the following sections will describe each option in more detail. Figure 16. M2 Mapping Options 5.7.2.1 M2 Configured as Output Disable If M2Config[2:0] is set to either ‘000’, ‘001’, or ‘010’, M2 becomes an output disable pin for one or both output pins. If M2 is driven ‘low’, the corresponding output(s) will be enabled, if M2 is driven ‘high’, the corresponding output(s) will be disabled. 5.7.2.2 M2 Configured as R-Mod Enable If M2Config[2:0] is set to ‘011’, M2 becomes the R-Mod enable pin. It should be noted that M2 is the only way to enable R-Mod. Even though the RModSel[1:0] modal parameter can be set arbi- trarily for each configuration set, it will not take effect unless enabled via M2. If M2 is driven ‘low’, R-Mod will be disabled, if M2 is driven ‘high’ R-Mod will be enabled. M2 pin Disable CLK_OUT and AUX_OUT pins Disable AUX_OUT pin Disable CLK_OUT pin RModSel[1:0] Modal Parameter Enable Force AuxOutSel[1:0] = 10 (PLL Clock Out) Reserved Force Manual Fractional N Source Selection M2Config[2:0] global parameter 000 001 010 011 100 101 110 111 FracNSrc Modal Parameter Override |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |