| Electronic Components Datasheet Search |
|
8757D Datasheet(PDF) 6 Page - Agilent(Hewlett-Packard) |
|
|
|||||||||||||||||||||||||||||
8757D Datasheet(HTML) 6 Page - Agilent(Hewlett-Packard) |
|
6 / 14 page ![]() 6 Transmission measurement accuracy Transmission loss or gain measurements are made relative to a 0 dB reference point established at calibration. Transmission measurement uncertainty = dynamic power accuracy + mismatch uncertainty Dynamic power accuracy is the measurement uncertainty due to the change in power level between calibration and the measurement. Mismatch uncertainty is the uncertainty due to reflections in the measurement setup. The frequency response errors of the source, detectors, bridge, and power splitter are removed via calibration. Transmission measurement uncertainty examples Assumptions: • Measurement frequency = 10 GHz • DUT input/output SWR = 1.5 • Ratio measurement Change in power after calibration <30 dB (+0 to –30 dBm range) 85037B 85025E Uncertainty component precision detector detector Dynamic accuracy (±dB) 0.11 0.40 Mismatch (±dB) 0.45 0.33 Total (±dB) 0.56 0.73 Change in power after calibration 60 dB (+6 to –55 dBm range) 85037B 85025E Uncertainty component precision detector detector Dynamic accuracy (±dB) 0.96 2.00 Mismatch (±dB) 0.45 0.33 Total (±dB) 1.41 2.33 Absolute power measurement accuracy This specification is useful for determining the accuracy of power measurements in dBm when using the Agilent 85037 series precision detectors or the 85025 series detectors in DC mode. Absolute power uncertainty = absolute power accuracy at 50 MHz + frequency response + mismatch uncertainty Absolute power measurement uncertainty examples Assumptions: • Measurement frequency = 10 GHz • DUT input/output SWR = 1.5 Power = +10 dBm 85037B 85025E Uncertainty component precision detector detector Absolute power accuracy at 50 MHz (±dB) 0.11 0.50 Frequency response (±dB) 0.18 0.50 Mismatch (±dB) 0.18 0.10 Total (±dB) 0.47 1.10 Power = 0 dBm 85037B 85025E Uncertainty component precision detector detector Absolute power accuracy at 50 MHz (±dB) 0.11 0.40 Frequency response (±dB) 0.18 0.50 Mismatch (±dB) 0.18 0.10 Total (±dB) 0.47 1.00 Power = 50 dBm 85037B 85025E Uncertainty component precision detector detector Absolute power accuracy at 50 MHz (±dB) 0.85 1.30 Frequency response (±dB) 0.18 0.50 Mismatch (±dB) 0.18 0.10 Total (±dB) 1.21 1.90 System accuracy |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |