| Electronic Components Datasheet Search |
|
SC3004 Datasheet(PDF) 7 Page - Silan Microelectronics Joint-stock |
|
|
|||||||||||||||||||||||||||||
SC3004 Datasheet(HTML) 7 Page - Silan Microelectronics Joint-stock |
|
7 / 9 page ![]() SC3004 HANGZHOU SILAN MICROELECTRONICS CO.,LTD REV:1.1 2005.12.15 Http: www.silan.com.cn Page 7 of 10 PCB WIRE LAYOUT SCHEMATIC Transmitting tube output ground line The transmitting tube ground line and IC ground line should layout separated or overstriking ground line. The above IC only use to hint, not to specified. Note: * In wire layout, the power filter capacitor should near to IC. * In wire layout, should avoid power line and ground line too long. * Recommended infrared transmit unit and IC ground line should layout separated, or over striking lines. * The emitter of triode connect 1 resistor at least. * Recommended triode use 9014. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|