| Electronic Components Datasheet Search |
|
AT89LP6440 Datasheet(PDF) 116 Page - ATMEL Corporation |
|
|
|||||||||||||||||||||||||||||
AT89LP6440 Datasheet(HTML) 116 Page - ATMEL Corporation |
|
116 / 194 page ![]() 116 3706A–MICRO–9/09 AT89LP6440 - Preliminary . Table 18-6. Status Codes for Master Transmitter Mode Status Code (TWSR) Status of the Two-wire Serial Bus and Two-wire Serial Interface Hardware Application Software Response Next Action Taken by TWI Hardware To/from TWDR To TWCR STA STO TWIF AA 0x08 A START condition has been transmitted Load SLA+W 0 0 1 X SLA+W will be transmitted; ACK or NOT ACK will be received 10h A repeated START condition has been transmitted Load SLA+W 0 0 1 X SLA+W will be transmitted; ACK or NOT ACK will be received Load SLA+R 0 0 1 X SLA+R will be transmitted; Logic will switch to Master Receiver mode 18h SLA+W has been transmitted; ACK has been received Load data byte 0 0 1 X Data byte will be transmitted and ACK or NOT ACK will be received No action 1 0 1 X Repeated START will be transmitted No action 0 1 1 X STOP condition will be transmitted andSTO flag will be reset No action 1 1 1 X STOP condition followed by a START condition will be transmitted and STO flag will be reset 20h SLA+W has been transmitted; NOT ACK has been received Load data byte 0 0 1 X Data byte will be transmitted and ACK or NOT ACK will be received No action 1 0 1 X Repeated START will be transmitted No action 0 1 1 X STOP condition will be transmitted and STO flag will be reset No action 1 1 1 X STOP condition followed by a START condition will be transmitted and STO flag will be reset 28h Data byte has been transmitted; ACK has been received Load data byte 0 0 1 X Data byte will be transmitted and ACK or NOT ACK will be received No action 1 0 1 X Repeated START will be transmitted No action 0 1 1 X STOP condition will be transmitted and STO flag will be reset No action 1 1 1 X STOP condition followed by a START condition will be transmitted and STO flag will be reset 30h Data byte has been transmitted; NOT ACK has been received Load data byte 0 0 1 X Data byte will be transmitted and ACK or NOT ACK will be received No actio 1 0 1 X Repeated START will be transmitted No actio 0 1 1 X STOP condition will be transmitted and STO flag will be reset No actio 1 1 1 X STOP condition followed by a START condition will be transmitted and STO flag will be reset 38h Arbitration lost in SLA+W or data bytes No action 0 0 1 X Two-wire Serial Bus will be released and not addressed slave mode entered No action 1 0 1 X A START condition will be transmitted when the bus becomes free |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |