| Electronic Components Datasheet Search |
|
33879 Datasheet(PDF) 16 Page - Freescale Semiconductor, Inc |
|
|
|||||||||||||||||||||||||||||
33879 Datasheet(HTML) 16 Page - Freescale Semiconductor, Inc |
|
16 / 23 page ![]() Analog Integrated Circuit Device Data 16 Freescale Semiconductor 33879 FUNCTIONAL DESCRIPTION SPI DEFINITION SPI DEFINITION On each SPI communication, a 16-bit command word is sent to the 33879 and a 16-bit status word is received from the 33879. The MSB is sent and received first. As Table shows, the Command Register defines the position and operation the 33879 will perform on rising edge of CS. The Fault Register, shown in Table 6, defines the previous state status of the output driver. Table identifies the type of fault and the method by which the fault is communicated to the microprocessor 0 = Bits 0 to 7, Output commanded OFF. 0 = Bits 8 to 15, Open Load Detection Current OFF. 1 = Bits 0 to 7, Output commanded ON. 1 = Bits 8 to 15 Open Load Detection Current ON. 0 = Bits 0 to 7, No Fault at Output. 1 = Bits 0 to 7, Output Short-to-Battery, Short-to-GND, Open Load, or TLIM. Bits 8 to 15 will always return “0”. Table 6. Command Register Definition MSB LSB Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 ON/ OFF Open Load Detect 8 ON/ OFF Open Load Detect 7 ON/ OFF Open Load Detect 6 ON/ OFF Open Load Detect 5 ON/ OFF Open Load Detect 4 ON/ OFF Open Load Detect 3 ON/ OFF Open Load Detect 2 ON/ OFF Open Load Detect 1 ON/ OFF OUT 8 ON/ OFF OUT 7 ON/ OFF OUT 6 ON/ OFF OUT 5 ON/ OFF OUT 4 ON/ OFF OUT 3 ON/ OFF OUT 2 ON/ OFF OUT 1 Table 7. Fault Register Definition MSB LSB Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 0 0 0 0 0 0 0 0 OUT 8 Status OUT 7 Status OUT 6 Status OUT 5 Status OUT 4 Status OUT 3 Status OUT 2 Status OUT 1 Status Table 8. Fault Operation Serial Output (DO) Pin Reports Over-temperature Fault reported by serial output (DO) pin. Over-current DO pin reports short to battery/supply or over-current condition. Output ON Open Load Fault Not reported. Output OFF Open Load Fault DO pin reports output OFF open load condition only with Open Load Detection Current enabled. DO pin will report “0” for Output OFF Open Load Fault with Open Load Detection Current disabled. Device Shutdowns Over-voltage Total device shutdown at VPWR = VPWR(OV) V. Resumes normal operation with proper voltage. All outputs assuming the previous state upon recovery from over-voltage. Over-temperature Only the output experiencing an over-temperature shuts down. Output assumes previous state upon recovery from over-temperature. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |