| Electronic Components Datasheet Search |
|
ST7532 Datasheet(PDF) 47 Page - Sitronix Technology Co., Ltd. |
|
|
|||||||||||||||||||||||||||||
ST7532 Datasheet(HTML) 47 Page - Sitronix Technology Co., Ltd. |
|
47 / 85 page ![]() ST7532 Ver 1.8 47/85 2006/9/18 (24) Read Register 1 (EPSRRD1) Command: 1 Parameter Byte: none (7CH) Execute the EPSRRD1 and STREAD (Status Read) commands in succession to read the Electronic Control value. A0 RD RW D7 D6 D5 D4 D3 D2 D1 D0 Command 0 1 0 0 1 1 1 1 1 0 0 Execute the Status Read command immediately after this command and execute the NOP command after the STREAD (Status Read) command. (25) Read Register 2 (EPSRRD2) Command: 1 Parameter Byte: none (7DH) Execute the EPSRRD2 and STREAD (Status Read) commands in succession to read the built-in resistance ratio. A0 RD RW D7 D6 D5 D4 D3 D2 D1 D0 Command 0 1 0 0 1 1 1 1 1 0 1 Execute the Status Read command immediately after this command and execute the NOP(Reset) command after the STREAD (Status Read) command. (26) Non-operating (NOP) - Parameter Byte: none (25H) This command does not affect the operation but has the function of canceling the IC test mode. Thus, it is recommended to enter it periodically to prevent malfunctioning due to noise and so on. A0 RD RW D7 D6 D5 D4 D3 D2 D1 D0 Command 0 1 0 0 0 1 0 0 1 0 1 (27) Status read (STREAD) - Parameter Byte: none The command is to read the internal condition of the IC. One status can be displayed depending on the setting status after reset or after NOP operation. A0 RD RW D7 D6 D5 D4 D3 D2 D1 D0 Command 0 0 1 Status data D7: Area scroll mode D6: Area scroll mode D5: RMW on/off D4: Scan direction D3: Display ON/OFF D2: EEPROM access D1: Display normal/inverse D0: Partial display Refer to SCM1 (ASCSET) Refer to SCM0 (ASCSET) 0 : Out 0 : Column 0 : OFF 0: OutAccess 0 : Inverse 0 : OFF 1 : In 1 : Line 1 : ON 1: InAccess 1 : Normal 1 : ON (28) Initial code (1) (EPINT) Command: 1; Parameter: 1 (07H) A0 RD RW D7 D6 D5 D4 D3 D2 D1 D0 Function Command 0 1 0 0 0 0 0 0 1 1 1 07H Parameter(P1) 1 1 0 0 0 0 1 1 0 0 1 19H This command is used for EEPROM internal ACK signal generating ,suggest using this command before EEPROM read/write operation . This command improve the EEPROM internal ACK signal under unstable power system. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |