  SS4005G Datasheet HTML 1Page - Silicon Standard Corp. SS4005G Datasheet HTML 2Page - Silicon Standard Corp. SS4005G Datasheet HTML 3Page - Silicon Standard Corp. SS4005G Datasheet HTML 4Page - Silicon Standard Corp. SS4005G Datasheet HTML 5Page - Silicon Standard Corp. SS4005G Datasheet HTML 6Page - Silicon Standard Corp. SS4005G Datasheet HTML 7Page - Silicon Standard Corp. SS4005G Datasheet HTML 8Page - Silicon Standard Corp. SS4005G Datasheet HTML 9Page - Silicon Standard Corp. Next Button
Zoom Inzoom in Zoom Outzoom out
 3 / 22 page
background image
www.SiliconStandard.com
3 of 22
Voltage Thresholds
In conjunction with monitoring the voltage at the I pin for
charge/discharge currents, the SS4005G also monitors
the battery potential through the V pin. The voltage
potential
is
determined
through
a
resistor-divider
network on tips of cells. The dividing factors of networks
are calculated during calibration and saved in the
EEPROM. The battery voltage is obtained by measuring
the input voltages on tips of cells and dividing factors
stored in EEPROM. The battery voltage is monitored for
battery LOW and battery EXHAUSTED (PLV and PEV).
An alarm warning will be sent to the host when battery
voltage is lower than PLV or PEV. Both PLV and PEV
are dynamically adjusted according to present load and
temperature. Exhausting charge threshold levels are
used to determine when the battery has reached a
programmable “empty” state. If the discharge current is
greater than the overload current value stored in the
EEPROM, PLV monitoring is disabled and resumes
after the current falls below the programmed value.
Reset
The SS4005G is in reset state when either
first
connected to the battery pack or receiving a RESET
command
from
SMBus.
Two
categories
of
reset
command, hard reset and soft reset, are acceptable
from the SMBus. On hard reset, the SS4005G initializes
and reads the EEPROM to configure the battery pack.
On soft reset, the SS4005G keeps the current state of
battery. The soft-RESET command is a byte command
with command code 0xF5. The hard-RESET command
is sent through manufacturer access data 0404.
Sleep mode
The SS4005G switches into sleep mode after detecting
no charge flow-through for more than 240 seconds. In
the sleep mode, most of the logic circuitry in the chip is
turned off to minimize the power consumption. SS4005G
will be awakened by either receiving an SBD command
or detecting a current flow through the sense resistor.
Measurement Operation
The SS4005G accumulates a measure of charge and
discharge
currents,
and
estimates
self-discharge.
Charge currents are compensated for temperature and
state-of-charge of the battery. The battery capacity,
denoted as Remaining Capacity (RCAP) in terms of
either current or power, represents the available battery
capacity at any given time. The charging increments the
RCAP,
while
the
discharging
and
self-discharging
decrement the RCAP. An internal register is used to
accumulate the amount of discharge to adjust the Full
Charge Capacity (FCCAP). FCCAP is updated only if a
complete battery discharges from full to empty occurs
without any partial battery charges. Therefore, the
SS4005G adapts its capacity determination based on
the actual conditions of discharge. The battery's initial
full capacity is set to the value stored in EEPROM. Until
FCCAP is updated, RCAP counts up to, but not beyond,
this threshold during subsequent charges. The battery’s
empty state is also programmed in the EEPROM. The
battery-low percentage stores the percentage of FCCAP
while the battery voltage drops to the PLV threshold.
1. Full Charge Capacity (FCCAP):
FCCAP is the latest measured discharge capacity of the
battery. On initialization, FCCAP is set to the value
stored in the EEPROM. During subsequent discharges,
FCCAP is updated with the latest recognized complete
discharging (or learning cycle), representing a discharge
from full to PLV, plus the battery low amount. A learning
cycle is necessary to update the FCCAP register. The
FCCAP also serves as the 100% reference threshold
used by the relative state-of-charge calculation and
display.
2. Design Capacity (DCAP):
The DCAP is the user-specified battery capacity and is
programmed in the external EEPROM. The DCAP also
provides the 100% reference for the absolute state-of-
charge calculation.
3. Remaining Capacity (RCAP ):
RCAP counts up during charge to a maximum value of
FCCAP and counts down to 0 during discharge and self-
discharge. RCAP is set to the battery low amount after
the PLV threshold has been reached. If RCAP is equal
to the battery low amount, RCAP keeps until voltage
drops below PLV threshold. To prevent overstatement of
charge during periods of overcharge, RCAP stops
incrementing when RCAP = FCCAP.
4. Cumulated Discharge Count (CDC):
The Cumulated Discharge Count is used to record the
usage of the battery which relates to the life of battery.
The CDC counts up during discharge independent of
RCAP and can continue increasing after RCAP has
decremented to 0. The CDC resets to 0 when CDC =
DCAP and the Cycle Count will be increased by 1.
Charge Counting
Charge activity is detected based on a positive voltage
on the I input. The voltage input at the I input is
measured and converted into current through the sense
resistor. If charge activity is detected, the SS4005G
increase the RCAP. Charge actions increment the
RCAP according to the cumulated charge counts. If the
measured current is lower than the threshold of the
digital filter and the digital filter is enabled, the charge
current is set as zero.
Discharge Counting
Discharge activity is detected based on a negative
voltage on the I input. The voltage input at the I input is
measured and converted into current through the sense
resistor. If discharge activity is detected, the SS4005G
decrease the RCAP. If the measured current is lower
SS4005G
7/16/2006 Rev.3.01



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com