Description  Smart Battery Gas Gauge for e-Bike
PDF  22 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  SSC [Silicon Standard Corp.]
Direct Link  http://www.siliconstandard.com
Logo SSC - Silicon Standard Corp.

SS4005G Datasheet(HTML) 8 Page - Silicon Standard Corp.

Back Button SS4005G Datasheet HTML 4Page - Silicon Standard Corp. SS4005G Datasheet HTML 5Page - Silicon Standard Corp. SS4005G Datasheet HTML 6Page - Silicon Standard Corp. SS4005G Datasheet HTML 7Page - Silicon Standard Corp. SS4005G Datasheet HTML 8Page - Silicon Standard Corp. SS4005G Datasheet HTML 9Page - Silicon Standard Corp. SS4005G Datasheet HTML 10Page - Silicon Standard Corp. SS4005G Datasheet HTML 11Page - Silicon Standard Corp. SS4005G Datasheet HTML 12Page - Silicon Standard Corp. Next Button
Zoom Inzoom in Zoom Outzoom out
 8 / 22 page
background image
www.SiliconStandard.com
8 of 22
SS4005G
7/16/2006 Rev.3.01
ManufacturerAccess() (0x00)
This function provides means to control the SS4005G
during normal operation and pack manufacturing. The
following commands are available.
01XX Engineer support command
02XX Engineer support command
03XX Calibration command:
0404 Reset (cold start, can be sealed)
05XX LED control command:
0501: LED test
0502: Normal mode
06XX Engineer support command
All the engineer support commands are used for
maintenance support only.
Input/Output: Set command and get return value in
certain sort of commands.
RemainingCapacityAlarm() (0x01)
This function sets or returns the remaining capacity
alarm value. When RemainingCapacity falls below the
RemainingCapacityAlarm value initialized from the
external EEPROM, the RemainingCapacityAlarm bit is
set in BatteryStatus. The system may alter this alarm
during operation.
Input/Output: unsigned integer. This sets/returns
the value where the RemainingCapacityAlarm
bit is set in Battery Status.
Units: mAh/10mWh
Range: 0 to 65,535
RemainingTimeAlarm() (0x02)
This function sets or returns the remaining time alarm
value. When the AverageTimeToEmpty falls below the
RemainingTimeAlarm value initialized from EEPROM,
the Remaining_Time_Alarm bit in BatteryStatus is set.
The system may alter this alarm during operation.
Input/Output: unsigned integer. This sets/returns
the value where the Remaining_Time_Alarm
bit is set in Battery Status.
Units: minutes
Range: 0 to 65,535 minutes
BatteryMode() (0x03)
This read/write word selects the various battery
operational modes. The lower byte is read-only, any
input data will be no effects on the lower byte. The
SS4005G support neither internal charge control nor
primary battery support. Bit definition is shown in
Table 2. Since bits 0 and 1 are 0s, bits 8 and 9 have
no effect. The SS4005G does support the battery
capacity information specified in both mAhr and
10mWh modes.
AtRate() (0x04)
This read/write word is the first half of a two-function
set used to set the AtRate value used in calculations
made by the AtRateTimeToFull() and
AtRateTimeToEmpty(). When the AtRate value is
positive, the AtRateTimeToFull function returns the
predicted time to charge full at the AtRate value of
charge. When the AtRate value is negative, the
AtRateTimeToEmpty function returns the predicted
operating time until charge empty at the AtRate value
of discharge.
Input/Output: signed integer. AtRate is positive for
charge and negative for discharge.
Units: mA/10mW
Range: -32,768 to 32,767
AtRateTimeToFull() (0x05)
This read-only word returns the predicted remaining
time to fully charge the battery at the AtRate value
(mA). The calculation is according to the latest set of
AtRate value.
Output: unsigned integer. Returns the predicted
time to full charge.
Units: minutes
Range: 0 to 65,534
Invalid Data Indication: 65,535 indicate that the
AtRate is a negative value.
AtRateTimeToEmpty() (0x06)
This read-only word returns the predicted remaining
operating time if the battery is discharged at the
AtRate value. The calculation is according to latest set
of AtRate value.
Output: unsigned integer. Returns the predicted
time to empty.
Units: minutes
Range: 0 to 65,534
Invalid Data Indication: 65,535 indicate that the
AtRate is a positive value.
AtRateOK() (0x07)
This read-only word returns a Boolean value that
indicates whether or not an additional load with AtRate
(mA) can be provided for longer than 10 seconds.
Boolean: Indicates if the battery can supply
additional energy with rate of AtRate (mA) for at
least 10 seconds.
Units: Boolean
Range: TRUE ??
0, FALSE = 0
Temperature() (0x08)
This read-only word returns the battery pack's internal
temperature.
Output: unsigned integer. Returns the cell
temperature in tenths of degrees Kelvin increments.
Units: 0.1°K
Range: 0 to +500.0°K
Accuracy: ? 2°K after calibration
Voltage() (0x09)
This read-only word returns the battery pack voltage
(mV).
Output: unsigned integer. Returns the battery
terminal voltage in mV.
Units: mV
Range: 0 to 65,535mV
Accuracy: ? 1% of DesignVoltage after calibration



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com