8 / 20 page ![]() 8 F 9/02 LNK501 Continuous mode designs can result in loop instability and are therefore not recommended. 3. A secondary output of 5 V with a Schottky rectifier diode. 4. Assumed efficiency of 70% 5. The part is board mounted with SOURCE pins soldered to sufficient area of copper to keep the die temperature at or below 100 °C. In addition to the thermal environment (sealed enclosure, ventilated, open frame, etc), the maximum power capability of LinkSwitch in a given application depends on transformer core size, efficiency, primary inductance tolerance, minimum specified input voltage, input storage capacitance, output voltage output diode forward drop etc., and can be different from the values shown in Table 1. In designs not required to meet 300 mW no-load consumption, the transformer can be designed with higher V OR to extend power capability as noted in the following section. Transformer Design To provide an approximately CV/CC output, the transformer should be designed to be discontinuous; all the energy stored in the transformer is transferred to the secondary during the MOSFET off time. Energy transfer in discontinuous mode is independent of line voltage. The peak power point prior to entering constant current operation is defined by the maximum power transferred by the transformer. The power transferred is given by the expression P = 0.5·L·I2·f, where L is the primary inductance, I2 is the primary peak current squared and f is the switching frequency. To simplify analysis, the data sheet parameter table specifies an I2f coefficient. This is the product of current limit squared and switching frequency normalized to the feedback parameter I DCT. This provides a single term that specifies the variation of the peak power point in the power supply due to LinkSwitch. As primary inductance tolerance is part of the expression that determines the peak output power point (start of the CC characteristic) this parameter should be well controlled. For an estimated overall output peak power tolerance of ±20% the primary inductance tolerance should be ±10% or better. This is achievable using standard low cost, center leg gapping techniques where the gap size is typically 0.08 mm or larger. Smaller gap sizes are possible but require non standard, tighter ferrite A L tolerances. Other gapping techniques such as film gapping allow tighter tolerances ( ±7% or better) with associated improvements in the tolerance of the peak power point. Please consult your transformer vendor for guidance. Core gaps should be uniform. Uneven core gapping, especially with small gap sizes, may cause variation in the primary inductance with flux density (partial saturation) and make the constant current region non-linear. To verify uniform gapping it is recommended that the primary current wave-shape be examined while feeding the supply from a DC source. The gradient is defined as di/dt = V/L and should remain constant throughout the MOSFET on time. Any change in gradient of the current ramp is an indication of uneven gapping. Measurements made using a LCR bridge should not be solely relied upon; typically these instruments only measure at currents of a few milliamps. This is insufficient to generate high enough flux densities in the core to show uneven gapping. For a typical EE13 core using center leg gapping, a 0.08 mm gap (A LG of 190 nH/t 2) allows a primary inductance tolerance of ±10% to be maintained in standard high volume production. This allows the EE13 to be used in designs up to 2.75 W. If film gapping is used then this increases to 3 W with less than 300 mW no-load consumption. Moving to a larger core, EE16 for example, allows a 3 W output with center leg gapping. The transformer turns ratio should be selected to give a V OR (output voltage reflected through secondary to primary turns ratio) of 40 - 60 V. In designs not required to meet 300 mW no- load consumption targets, the transformer can be designed with higher V OR as long as discontinuous mode operation is maintained. This increases the output power capability. For example, a 230 VAC input design using an EE19 transformer core with V OR >70 V, is capable of delivering up to 5 W typical output power. Note: the linearity of the CC region of the power supply output characteristic is influenced by V OR. If this is an important aspect of the application, the output characteristic should be checked before finalizing the design. Output Characteristic Variation Both the device tolerance and external circuit govern the overall tolerance of the LinkSwitch output characteristic. Estimated peak power point tolerances for a 2.75 W design are ±10% for voltage and ±20% for current limit for overall variation in high volume manufacturing. This includes device and transformer tolerances and line variation. Lower power designs may have poorer constant current linearity. As the output load reduces from the peak power point, the output voltage will tend to rise due to tracking errors compared to the load terminals. Sources of these errors include the output cable drop, output diode forward voltage and leakage inductance, which is the dominant cause. As the load reduces, the primary operating peak current reduces, together with the leakage inductance energy, which reduces the peak charging of the clamp capacitor. With a primary leakage inductance of 50 µH, the output voltage typically rises 30% over a 100% to 5% load change. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |