Back Button KP461 Datasheet HTML 13Page - Vishay Siliconix KP461 Datasheet HTML 14Page - Vishay Siliconix KP461 Datasheet HTML 15Page - Vishay Siliconix KP461 Datasheet HTML 16Page - Vishay Siliconix KP461 Datasheet HTML 17Page - Vishay Siliconix KP461 Datasheet HTML 18Page - Vishay Siliconix KP461 Datasheet HTML 19Page - Vishay Siliconix KP461 Datasheet HTML 20Page - Vishay Siliconix KP461 Datasheet HTML 21Page - Vishay Siliconix Next Button
Zoom Inzoom in Zoom Outzoom out
 17 / 29 page
background image
2002 Oct 09
17
BCcomponents
Product specification
Polypropylene film foil capacitors
KP 460 to 464
CONSTRUCTION
Description
• Low-inductive wound cell of metal foil and a
polypropylene film
• Protected by a hard, water-repellent solvent-resistant blue
epoxy lacquer
• Axial iron leads, solder-coated.
Mounting
NORMAL USE
The capacitors are suitable for vertical or horizontal
mounting on printed-circuit boards. The capacitors packed
on bandoliers are designed for mounting on printed-circuit
boards by means of automatic insertion machines.
Fig.10 Construction.
144x12(halfpage)
connecting wire
lead - tin foil
polypropylene film
CBA371
SPECIFIC METHOD OF MOUNTING TO WITHSTAND VIBRATION
AND SHOCK
The capacitors shall be mechanically fixed by the leads.
SOLDERING CONDITIONS
The capacitance stability is dependent on the maximum
temperature the capacitor reaches during soldering.
Figure 11 shows the typical effect of
∆C/C as a function of
soldering time under the worst possible mounting
conditions (horizontal on the PCB, minimum possible pitch)
and with 80
°C preheating.
Storage temperature
• Storage temperature: Tstg =−25 to +40 °C with RH
maximum 80% without condensation.
RATINGS AND CHARACTERISTICS REFERENCE
CONDITIONS
Unless otherwise specified, all electrical values apply to an
ambient free air temperature of 23
±1 °C, an atmospheric
pressure of 86 to 106 kPa and a relative humidity of
50
±2%.
For reference testing, a conditioning period shall be applied
over 96
±4 hours by heating the products in a circulating air
oven at the rated temperature and a relative humidity not
exceeding 20%.
Fig.11
∆C/C as a function of soldering time.∆C/C
296x12(full_width)
CBA372
∆C/C
(%)
10
0.4
0
-0.4
-0.8
02
4
6
8
soldering time (s)



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com