Back Button UCD90124 Datasheet HTML 13Page - Texas Instruments UCD90124 Datasheet HTML 14Page - Texas Instruments UCD90124 Datasheet HTML 15Page - Texas Instruments UCD90124 Datasheet HTML 16Page - Texas Instruments UCD90124 Datasheet HTML 17Page - Texas Instruments UCD90124 Datasheet HTML 18Page - Texas Instruments UCD90124 Datasheet HTML 19Page - Texas Instruments UCD90124 Datasheet HTML 20Page - Texas Instruments UCD90124 Datasheet HTML 21Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 17 / 46 page
background image
1M
1000 pF
+3.3V
MONx
280k
TEMP_BIAS
(GPO)
UCD90124
www.ti.com
SLVSA29A – NOVEMBER 2009 – REVISED DECEMBER 2009
The device supports multiple PMBus commands related to current, including READ_IOUT, which reads external
currents
from
the
MON
pins;
IOUT_OC_FAULT_LIMIT,
which
sets
the
overcurrent
fault
limit;
IOUT_OC_WARN_LIMIT, which sets the overcurrent warning limit; and IOUT_UC_FAULT_LIMIT, which sets the
undercurrent fault limit. The UCD90xxx Sequencer and System Health Controller PMBus Command Reference
contains a detailed description of how current fault responses are implemented using PMBus commands.
IOUT_CAL_GAIN is a PMBus command that allows the scale factor of an external current sensor and any
amplifiers or attenuators between the current sensor and the MON pin to be entered by the user in milliohms.
IOUT_CAL_OFFSET is the current that results in 0 V at the MON pin. The combination of these PMBus
commands allows current to be reported in amperes.
REMOTE TEMPERATURE MONITORING AND INTERNAL TEMPERATURE SENSOR
The UCD90124 has support for internal and remote temperature sensing. The internal temperature sensor
requires no calibration and can report the device temperature via the PMBus interface. The remote temperature
sensor can report the remote temperature by using a configurable gain and offset for the type of sensor that is
used in the application [P-N junction or a linear temperature sensor (LTS)] connected to the analog inputs.
External circuitry must be used in order to convert the temperature to a voltage within the range of the
UCD90124 MONx input being used.
If an input is configured as a temperature, the measurements are smoothed by a sliding average digital filter with
a time constant of approximately 12.4 seconds. The filter reduces the probability of false fault detections, and
introduces a small delay to the temperature reading. The internal device temperature is measured using a silicon
diode sensor with an accuracy of ±5°C and is also monitored using the ADC. Temperature monitoring begins
immediately after reset and initialization.
The device supports multiple PMBus commands related to temperature, including READ_TEMPERATURE_1,
which reads the internal temperature; READ_TEMPERATURE_2, which reads external temperatures; and
OT_FAULT_LIMIT and OT_WARN_LIMIT, which set the overtemperature fault and warning limit. The UCD90xxx
Sequencer and System Health Controller PMBus Command Reference contains a detailed description of how
temperature-fault responses are implemented using PMBus commands.
TEMPERATURE_CAL_GAIN is a PMBus command that allows the scale factor of an external temperature
sensor and any amplifiers or attenuators between the temperature sensor and the MON pin to be entered by the
user in °C/V. TEMPERATURE_CAL_OFFSET is the temperature that results in 0 V at the MON pin. The
combination of these PMBus commands allows temperature to be reported in degrees Celsius.
Diode sensors require a different sensing technique. The UCD90124 measures the diode voltage at two different
bias current settings. The UCD90124 calculates the temperature based on the difference between these two
voltages using TEMPERATURE_CAL_GAIN and TEMPERATURE_CAL_OFFSET settings. Figure 11 shows a
typical diode temperature-sensing circuit. When the Ibias source in the UCD90124 is off, the current through the
diode is (3.3 V – 0.3 V) / 1M
Ω = ~3 µA. When the Ibias source is on, the diode current is ~3 µA + 10 µA = 13
µA.
To reduce noise on the temperature measurement, a 1000-pF capacitor is recommended to be placed at the
MONx input used to measure temperature.
Figure 11. Diode Temperature-Sense Circuit
Copyright © 2009, Texas Instruments Incorporated
Submit Documentation Feedback
17
Product Folder Link(s) :UCD90124



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com