| Electronic Components Datasheet Search |
|
UCD90124 Datasheet(PDF) 18 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
UCD90124 Datasheet(HTML) 18 Page - Texas Instruments |
|
18 / 46 page ![]() PMBUS_CNTRL PIN RAIL 1 EN RAIL 1 VOLTAGE RAIL 2 EN RAIL 2 VOLTAGE POWER_GOOD_ON[1] TON_DELAY[2] TOFF_DELAY[1] TOFF_DELAY[2] Rail 1 andRail 2 arebothsequenced “ON” and “OFF” bythePMBUS_CNTRL pinonly Rail 2 hasRail 1 asan “ON” dependency Rail 1 hasRail 2 asaFaultShutdownSlave TON_DELAY[1] VOUT_OV_FAULT _LIMIT VOUT_UV_FAULT _LIMIT MAX_GLITCH_TIME TIMEBETWEEN RESTARTS MAX_GLITCH_TIME + TOFF_DELAY[1] MAX_GLITCH_TIME TIMEBETWEEN RESTARTS Rail 1 issettousetheglitchfilterforUVorOVevents Rail 1 issettoRESTART 3 timesafteraUVorOVevent Rail 1 issettoshutdownwithdelayforaOVevent TIMEBETWEEN RESTARTS MAX_GLITCH_TIME + TOFF_DELAY[1] MAX_GLITCH_TIME TOFF_DELAY[1] PMBUS_CNTRL PIN RAIL 1 EN RAIL 1 VOLTAGE TON_MAX_FAULT_LIMIT[1] RAIL 2 EN RAIL 2 VOLTAGE POWER_GOOD_ON[1] TON_DELAY[2] TON_DELAY[1] TON_MAX_FAULT_LIMIT[1] POWER_GOOD_ON[1] TimeBetweenRestarts Rail1andRail2arebothsequenced “ON” and “OFF” bythePMBUS_CNTRL pinonly Rail2hasRail1asan “ON” dependency Rail1issettoshutdownimmediately andRESTART 1timeincaseofa Time OnMaxfault UCD90124 SLVSA29A – NOVEMBER 2009 – REVISED DECEMBER 2009 www.ti.com FAULT RESPONSES AND ALARM PROCESSING Software monitors that the rail stays within a window of normal operation. There are two programmable warning levels (under and over) and two programmable fault levels (under and over). When any monitored voltage, current, or temperature goes outside of the warning or fault window, the PMBALERT# pin is asserted immediately, and the appropriate bits are set in the PMBus status registers (see Figure 9). Detailed descriptions of the status registers are provided in the UCD90xxx Sequencer and System Health Controller PMBus Command Reference and the PMBus Specification. A programmable glitch filter can be enabled or disabled for each MON input. A glitch filter for an input defined as a voltage can be set between 0 and 102 ms with 400- μs resolution. A glitch filter for an input defined as a current or temperature can be between 0 and 25.5 seconds with 100-ms resolution. The longer time constants are due to the fixed low-pass digital filters associated with current and temperature inputs. Fault-response decisions are based on results from the 12-bit ADC. The device cycles through the ADC results and compares them against the programmed limits. The time to respond to an individual event is determined by when the event occurs within the ADC conversion cycle and the selected fault response. Figure 12. Sequencing and Fault-Response Timing Figure 13. Maximum Turnon Fault The configurable fault limits are: Maximum turnon fault – Flagged if a rail that is enabled does not reach the POWER_GOOD_ON limit within the configured time Undervoltage warning – Flagged if a voltage rail drops below the specified UV warning limit after reaching the POWER_GOOD_ON setting 18 Submit Documentation Feedback Copyright © 2009, Texas Instruments Incorporated Product Folder Link(s) :UCD90124 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |