Back Button UCD90124RGCT Datasheet HTML 12Page - Texas Instruments UCD90124RGCT Datasheet HTML 13Page - Texas Instruments UCD90124RGCT Datasheet HTML 14Page - Texas Instruments UCD90124RGCT Datasheet HTML 15Page - Texas Instruments UCD90124RGCT Datasheet HTML 16Page - Texas Instruments UCD90124RGCT Datasheet HTML 17Page - Texas Instruments UCD90124RGCT Datasheet HTML 18Page - Texas Instruments UCD90124RGCT Datasheet HTML 19Page - Texas Instruments UCD90124RGCT Datasheet HTML 20Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 16 / 46 page
background image
UCD90124
SLVSA29A – NOVEMBER 2009 – REVISED DECEMBER 2009
www.ti.com
VOLTAGE MONITORING
Up to 13 voltages can be monitored using the analog input pins. The input voltage range is 0 V–2.5 V for MON
pins 1–6, 59, 62 and 63. Pins 50, 52, 54, and 56 can measure down to 0.2 V. Any voltage between 0 V and 0.2
V on these pins is read as 0.2 V. External resistors can be used to attenuate voltages higher than 2.5 V.
The ADC operates continuously, requiring 3.89
μs to convert a single analog input and 54.5 μs to convert all 14
of the analog inputs, including the onboard temperature sensor. Each rail is sampled by the sequencing and
monitoring algorithm every 400
μs. The maximum source impedance of any sampled voltage should be less than
4 k
Ω. The source impedance limit is particularly important when a resistor-divider network is used to lower the
voltage applied to the analog input pins.
MON pins selected for rail 1 through rail 6 have optional digital hardware comparators, which can be used to
achieve faster fault responses. Each hardware comparator has two thresholds (one UV and one OV) as opposed
to four software thresholds. The hardware comparators respond to UV or OV conditions in about 80
μs (faster
than 400 µs for the ADC inputs) and can be used to disable rails or assert GPOs. The only fault response
available for the hardware comparators is to shut down immediately.
An internal 2.5-V reference is used by the ADC. The ADC reference has a tolerance of ±0.5% between 0°C and
125°C and a tolerance of ±1% between –40°C and 125°C. An external voltage divider is required for monitoring
voltages higher than 2.5 V. The nominal rail voltage and the external scale factor can be entered into the Fusion
GUI and are used to report the actual voltage being monitored instead of the ADC input voltage. The nominal
voltage is used to set the range and precision of the reported voltage according to Table 1.
Table 1. Voltage Range and Resolution
VOLTAGE RANGE
RESOLUTION
(Volts)
(millivolts)
0 to 127.99805
1.95313
0 to 63.99902
0.97656
0 to 31.99951
0.48828
0 to 15.99976
0.24414
0 to 7.99988
0.12207
0 to 3.99994
0.06104
0 to 1.99997
0.03052
0 to 0.99998
0.01526
Although the monitor results can be reported with a resolution of about 15
μV, the real conversion resolution of
610
μV is fixed by the 2.5-V reference and the 12-bit ADC.
The MON pins can directly measure voltages, but each input can be defined as a voltage, current,or
temperature. A single rail can include all three measurement types, each monitored on separate MON pins. If a
rail has both voltage and current assigned to it, then power can be calculated and reported for the rail. Digital
filtering applied to each MON input depends on the type of signal. Voltage inputs have no filtering. Current inputs
have a low-pass filter with a time constant of about 1 second. Temperature inputs have a low-pass filter with a
time constant of about 12.4 seconds.
CURRENT MONITORING
Current can be monitored using the analog inputs. External circuitry must be used in order to convert the current
to a voltage within the range of the UCD90124 MONx input being used.
If a monitor input is configured as a current, the measurements are smoothed by a sliding-average digital filter
with a time constant of approximately 1 second. The filter reduces the probability of false fault detections, and
introduces a small delay to the current reading. If a rail is defined with a voltage monitor and a current monitor,
then monitoring for undercurrent warnings begins once the rail voltage reaches POWER_GOOD_ON. If the rail
does not have a voltage monitor, then current monitoring begins after TON_DELAY.
16
Submit Documentation Feedback
Copyright © 2009, Texas Instruments Incorporated
Product Folder Link(s) :UCD90124



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com