| Electronic Components Datasheet Search |
|
SC667 Datasheet(PDF) 40 Page - Semtech Corporation |
|
|
|||||||||||||||||||||||||||||
SC667 Datasheet(HTML) 40 Page - Semtech Corporation |
|
40 / 47 page ![]() SC667 40 Group #1 Target and Start Times Register (10h) This register is used to set the duration that the backlights will stay at the start value and at the target value. This feature provides additional customization of the breathe and blink lighting effects. Register 10h will only effect banks that are assigned to group #1. TT1_2, TT1_1, and TT1_0 [D5:D3] These bits set the duration that backlights will stay at the target value. These bits effect only banks assigned to group #1. Target times are given in Table 18. Table 18 — Target Time (Group #1) TT1_2 TT1_1 TT1_0 Target Time (ms) 0 0 0 32 0 0 1 64 0 1 0 256 0 1 1 512 1 0 0 1024 1 0 1 2048 1 1 0 3072 1 1 1 4096 ST1_2, ST1_1, and ST1_0 [D2:D0] These bits set the duration of time that backlights will stay at the starting value. These bits effect only banks assigned to group #1. Start times are given in Table 19. Table 19 — Start Time (Group #1) ST1_2 ST1_1 ST1_0 Start Time (ms) 0 0 0 32 0 0 1 64 0 1 0 256 0 1 1 512 1 0 0 1024 1 0 1 2048 1 1 0 3072 1 1 1 4096 Register Map (continued) Group #2 Target and Start Times Register (11h) This register is used to set the duration that the backlights will stay at the start value and at the target value. This feature provides additional customization of the breathe and blink lighting effects. Register 11h will only effect banks that are assigned to group #2. TT2_2, TT2_1, and TT2_0 [D5:D3] These bits set the duration that backlights will stay at the target value. These bits effect only banks assigned to group #2. Target times are given in Table 20. Table 20 — Target Time (Group #2) TT2_2 TT2_1 TT2_0 Target Time (ms) 0 0 0 32 0 0 1 64 0 1 0 256 0 1 1 512 1 0 0 1024 1 0 1 2048 1 1 0 3072 1 1 1 4096 ST2_2, ST2_1, and ST2_0 [D2:D0] These bits set the duration that backlights will stay at the starting value. These bits effect only banks assigned to group #2. Start times are given in Table 21. Table 21 — Start Time (Group #2) ST2_2 ST2_1 ST2_0 Start Time (ms) 0 0 0 32 0 0 1 64 0 1 0 256 0 1 1 512 1 0 0 1024 1 0 1 2048 1 1 0 3072 1 1 1 4096 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |