13 / 20 page ![]() ADIS16305 Rev. 0 | Page 13 of 20 CALIBRATION Manual Bias Calibration The bias offset registers in Table 16 and Table 17 provide a manual adjustment function for the output of each sensor. For example, if GYRO_OFF = 0x1FF6 (DIN = 0x9B1F, 0x9AF6), the GYRO_OUT offset shifts by −10 LSBs, or −0.125°/sec. Table 16. GYRO_OFF Bit Descriptions Bits Description (Default = 0x0000) [15:13] Not used. [12:0] Data bits. Twos complement, 0.0125°/sec per LSB. Typical adjustment range = ±50°/sec. Table 17. XACCL_OFF, YACCL_OFF, ZACCL_OFF Bit Descriptions Bits Description (Default = 0x0000) [15:12] Not used. [11:0] Data bits. Twos complement, 0.6 mg/LSB. Typical adjustment range = ±1.22 g. Frame Alignment The PITCH_OFF and ROLL_OFF registers (see Table 18) provide the angular orientation difference between the inertial frame (internal) and the external frame (package). They follow the same orientation as PITCH_OUT and ROLL_OUT, as shown in Figure 14. Table 18. PITCH_OFF, ROLL_OFF Bit Descriptions Bits Description [15:10] Not used. [9:0] Data bits. Twos complement, 0.014°/LSB. Gyroscope Automatic Bias Null Calibration Set GLOB_CMD[0] = 1 (DIN = 0xBE01) to execute the automatic bias null calibration function. This function measures the gyroscope output register and then loads the gyroscope offset register with the opposite value to provide a quick bias calibration. All sensor data is then reset to 0, and the flash memory is updated automatically within 50 ms (see Table 19). Gyroscope Precision Automatic Bias Null Calibration Set GLOB_CMD[4] = 1 (DIN = 0xBE10) to execute the precision automatic bias null calibration function. This function takes the sensor offline for 30 sec while it collects a set of data and calculates more accurate bias correction factors for each gyroscope. After this function is executed, the newly calculated correction factor is loaded into the gyroscope offset registers, all sensor data is reset to 0, and the flash memory is updated automatically within 50 ms (see Table 19). Restoring Factory Calibration Set GLOB_CMD[1] = 1 (DIN = 0xBE02) to execute the factory calibration restore function. This function resets each user calibration register to 0x0000 (see Table 16 and Table 17), resets all sensor data to 0, and automatically updates the flash memory within 50 ms (see Table 19). Linear Acceleration Bias Compensation (Gyroscope) Set MSC_CTRL[7] = 1 (DIN = 0xB486) to enable correction for low frequency acceleration influences on gyroscope bias. Note that the DIN sequence also preserves the factory default condition for the data-ready function (see Table 24). OPERATIONAL CONTROL Global Commands The GLOB_CMD register provides trigger bits for several useful functions. Setting the assigned bit to 1 starts each operation, which returns the bit to 0 after completion. For example, set GLOB_CMD[7] = 1 (DIN = 0xBE80) to execute a software reset, which stops the sensor operation and runs the device through its start-up sequence. This sequence includes loading the control registers with their respective flash memory locations prior to producing new data. Reading the GLOB_CMD register (DIN = 0x3E00) starts the burst read sequence. Table 19. GLOB_CMD Bit Descriptions Bit(s) Description [15:8] Not used [7] Software reset command [6:5] Not used [4] Precision autonull command [3] Flash update command [2] Auxiliary DAC data latch [1] Factory calibration restore command [0] Autonull command Internal Sample Rate The SMPL_PRD register provides discrete sample rate settings using the bit assignments in Table 20 and the following equation: tS = tB × (NS + 1) For example, when SMPL_PRD[7:0] = 0x0A, the sample rate is 149 SPS. Table 20. SMPL_PRD Bit Descriptions Bit(s) Description (Default = 0x0001) [15:8] Not used [7] Time base (tB) 0 = 0.61035 ms, 1 = 18.921 ms [6:0] Increment setting (NS) Internal sample period = tS = tB × (NS + 1) The default sample rate setting of 819.2 SPS provides optimal performance. For systems that value slower sample rates, keep the internal sample rate at 819.2 SPS. Use the programmable filter (SENS_AVG) to reduce the bandwidth, which helps to prevent aliasing. The data-ready function (MSC_CTRL) can drive an interrupt routine that uses a counter to help ensure data coherence at reduced rates. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |