| Electronic Components Datasheet Search |
|
DDA010 Datasheet(PDF) 7 Page - Infineon Technologies AG |
|
|
|||||||||||||||||||||||||||||
DDA010 Datasheet(HTML) 7 Page - Infineon Technologies AG |
|
7 / 21 page ![]() Version 2.3 7 April 27, 2010 CoolSET ® - Q1 ICE2QR0665 Functional Description 3 Functional Description 3.1 VCC Pre-Charging and Typical VCC Voltage During Start-up In ICE2QR0665, a startup cell is integrated into the depletion CoolMOS ®. As shown in Figure 2, the start cell consists of a high voltage device and a controller, whereby the high voltage device is controlled by the controller. The startup cell provides a pre-charging of the VCC capacitor till VCC voltage reaches the VCC turned-on threshold V VCCon and the IC begins to operate. Once the mains input voltage is applied, a rectified voltage shows across the capacitor C bus. The high voltage device provides a current to charge the VCC capacitor C vcc. Before the VCC voltage reaches a certain value, the amplitude of the current through the high voltage device is only determined by its channel resistance and can be as high as several mA. After the VCC voltage is high enough, the controller controls the high voltage device so that a constant current around 1mA is provided to charge the VCC capacitor further, until the VCC voltage exceeds the turned-on threshold V VCCon. As shown as the time phase I in Figure 3, the VCC voltage increase near linearly and the charging speed is independent of the mains voltage level. Figure 3 VCC voltage at start up The time taking for the VCC pre-charging can then be approximately calculated as: [1] where I VCCcharge2 is the charging current from the startup cell which is 1.05mA, typically. Exceeds the VCC voltage the turned-on threshold V VCCon of at time t1, the startup cell is switched off, and the IC begins to operate with a soft-start. Due to power consumption of the IC and the fact that still no energy from the auxiliary winding to charge the VCC capacitor before the output voltage is built up, the VCC voltage drops (Phase II). Once the output voltage is high enough, the VCC capacitor receives then energy from the auxiliary winding from the time point t 2 on. The VCC then will reach a constant value depending on output load. 3.2 Soft-start As shown in Figure 4, at the time t on, the IC begins to operate with a soft-start. By this soft-start the switching stresses for the switch, diode and transformer are minimised. The soft-start implemented in ICE2QR0665 is a digital time-based function. The preset soft-start time is 12ms with 4 steps. If not limited by other functions, the peak voltage on CS pin will increase step by step from 0.32V to 1V finally. Figure 4 Maximum current sense voltage during softstart 3.3 Normal Operation The PWM controller during normal operation consists of a digital signal processing circuit including an up/down counter, a zero-crossing counter (ZC counter) and a comparator, and an analog circuit including a current measurement unit and a comparator. The switch-on and -off time points are each determined by the digital circuit and the analog circuit, respectively. As input information for the switch-on determination, the zero-crossing input signal and the value of the up/down counter are needed, while the feedback signal V FB and the current sensing signal VCS are necessary for the switch-off determination. Details about the full operation of the PWM controller in normal operation are illustrated in the following paragraphs. 3.3.1 Digital Frequency Reduction As mentioned above, the digital signal processing circuit consists of an up/down counter, a ZC counter and a comparator. These three parts are key to implement digital frequency reduction with decreasing load. In addition, a ringing suppression time controller is implemented to avoid mistriggering by the high frequency oscillation, when the output voltage is very low under conditions such as soft start or output short circuit . Functionality of these parts is described as in the following. 3.3.1.1 Up/down counter The up/down counter stores the number of the zero crossing to be ignored before the main power switch is switched on VVCCon VVCC VVCCoff t1 t t2 iii iii t 1 V VCCon C vcc ⋅ I VCCch e2 arg ------------------------------------------ = ton 369 12 0.32 0.49 0.66 0.83 1.00 Vcs_sst (V) Time(ms) |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |