| Electronic Components Datasheet Search |
|
DDA010 Datasheet(PDF) 9 Page - Infineon Technologies AG |
|
|
|||||||||||||||||||||||||||||
DDA010 Datasheet(HTML) 9 Page - Infineon Technologies AG |
|
9 / 21 page ![]() CoolSET ® - Q1 ICE2QR0665 Functional Description Version 2.3 9 April 27, 2010 thedetected zero-crossing to the switch-on of the main switch t delay, theoretically: [2] This time delay should be matched by adjusting the time constant of the RC network which is calculated as: [3] 3.3.1.3 Ringing suppression time After MOSFET is turned off, there will be some oscillation on V DS, which will also appear on the voltage on ZC pin. To avoid that the MOSFET is turned on mistriggerred by such oscillations, a ringing suppression timer is implemented. The time is dependent on the voltage v ZC. When the voltage vZC is lower than the threshold V ZCRS, a longer preset time applies, while a shorter time is set when the voltage v ZC is higher than the threshold. 3.3.1.4 Switch on determination After the gate drive goes to low, it can not be changed to high during ring suppression time. After ring suppression time, the gate drive can be turned on when the ZC counter value is higher or equal to up/down counter value. However, it is also possible that the oscillation between primary inductor and drain-source capacitor damps very fast and IC can not detect enough zero crossings and ZC counter value will not be high enough to turn on the gate drive. In this case, a maximum off time is implemented. After gate drive has been remained off for the period of T OffMax, the gate drive will be turned on again regardless of the counter values and V ZC. This function can effectively prevent the switching frequency from going lower than 20kHz, otherwise which will cause audible noise, during start up. 3.3.2 Switch Off Determination In the converter system, the primary current is sensed by an external shunt resistor, which is connected between low-side terminal of the main power switch and the common ground. The sensed voltage across the shunt resistor v CS is applied to an internal current measurement unit, and its output voltage V 1 is compared with the regulation voltage V FB. Once the voltage V 1 exceeds the voltage VFB, the output flip-flop is reset. As a result, the main power switch is switched off. The relationship between the V 1 and the vCS is described by: [4] To avoid mistriggering caused by the voltage spike across the shunt resistor at the turn on of the main power switch, a leading edge blanking time, t LEB, is applied to the output of the comparator. In other words, once the gate drive is turned on, the minimum on time of the gate drive is the leading edge blanking time. In addition, there is a maximum on time, t OnMax, limitation implemented in the IC. Once the gate drive has been in high state longer than the maximum on time, it will be turned off to prevent the switching frequency from going too low because of long on time. 3.4 Current Limitation There is a cycle by cycle current limitation realized by the current limit comparator to provide an overcurrent detection. The source current of the MOSFET is sensed via a sense resistor R CS. By means of R CS the source current is transformed to a sense voltage V CS which is fed into the pin CS. If the voltage V CS exceeds an internal voltage limit, adjusted according to the Mains voltage, the comparator immediately turns off the gate drive. To prevent the Current Limitation process from distortions caused by leading edge spikes, a Leading Edge Blanking time (t LEB) is integrated in the current sensing path. A further comparator is implemented to detect dangerous current levels (V CSSW) which could occur if one or more transformer windings are shorted or if the secondary diode is shorted. To avoid an accidental latch off, a spike blanking time of t CSSW is integrated in the output path of the comparator . 3.4.1 Foldback Point Correction When the main bus voltage increases, the switch on time becomes shorter and therefore the operating frequency is also increased. As a result, for a constant primary current limit, the maximum possible output power is increased, which the converter may have not been designed to support. To avoid such a situation, the internal foldback point correction circuit varies the V CS voltage limit according to the bus voltage. This means the V CS will be decreased when the bus voltage increases. To keep a constant maximum input power of the converter, the required maximum V CS ∆t T osc 4 ------------ t delay – = τ td C zc R zc1 R zc2 ⋅ R zc1 R zc2 + --------------------------------- ⋅ = V 1 3.3 V cs ⋅ 0.7 + = |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |